{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-38303","assignerOrgId":"c550e75a-17ff-4988-97f0-544cde3820fe","state":"PUBLISHED","assignerShortName":"dell","dateReserved":"2024-06-13T14:41:01.527Z","datePublished":"2024-08-29T04:34:53.178Z","dateUpdated":"2024-08-29T13:49:36.661Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"PowerEdge Platform","vendor":"Dell","versions":[{"lessThan":"2.22.1","status":"affected","version":"N/A","versionType":"semver"},{"lessThan":"2.22.0","status":"affected","version":"N/A","versionType":"semver"}]}],"credits":[{"lang":"en","type":"finder","value":"Dell would like to thank codebreaker1337 for reporting this issue."}],"datePublic":"2024-08-28T06:30:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Dell PowerEdge Platform, 14G Intel BIOS version(s) prior to 2.22.x, contains an Improper Input Validation vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure."}],"value":"Dell PowerEdge Platform, 14G Intel BIOS version(s) prior to 2.22.x, contains an Improper Input Validation vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure."}],"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"LOCAL","availabilityImpact":"NONE","baseScore":5.3,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"HIGH","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:N/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-20","description":"CWE-20: Improper Input Validation","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"c550e75a-17ff-4988-97f0-544cde3820fe","shortName":"dell","dateUpdated":"2024-08-29T04:34:53.178Z"},"references":[{"tags":["vendor-advisory"],"url":"https://www.dell.com/support/kbdoc/en-us/000228135/dsa-2024-309-security-update-for-dell-poweredge-server-for-improper-input-validation-vulnerability"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-08-29T13:49:25.085284Z","id":"CVE-2024-38303","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-08-29T13:49:36.661Z"}}]}}