{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-37996","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","state":"PUBLISHED","assignerShortName":"siemens","dateReserved":"2024-06-11T08:32:52.184Z","datePublished":"2024-07-09T12:05:04.781Z","dateUpdated":"2025-08-27T20:42:54.503Z"},"containers":{"cna":{"providerMetadata":{"orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens","dateUpdated":"2024-10-08T08:40:13.781Z"},"descriptions":[{"lang":"en","value":"A vulnerability has been identified in JT Open (All versions < V11.5), JT2Go (All versions < V2406.0003), PLM XML SDK (All versions < V7.1.0.014), Teamcenter Visualization V14.2 (All versions < V14.2.0.13), Teamcenter Visualization V14.3 (All versions < V14.3.0.11), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0003). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted XML files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."}],"affected":[{"vendor":"Siemens","product":"JT Open","versions":[{"status":"affected","version":"0","lessThan":"V11.5","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"JT2Go","versions":[{"status":"affected","version":"0","lessThan":"V2406.0003","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"PLM XML SDK","versions":[{"status":"affected","version":"0","lessThan":"V7.1.0.014","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Teamcenter Visualization V14.2","versions":[{"status":"affected","version":"0","lessThan":"V14.2.0.13","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Teamcenter Visualization V14.3","versions":[{"status":"affected","version":"0","lessThan":"V14.3.0.11","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Teamcenter Visualization V2312","versions":[{"status":"affected","version":"0","lessThan":"V2312.0008","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Teamcenter Visualization V2406","versions":[{"status":"affected","version":"0","lessThan":"V2406.0003","versionType":"custom"}],"defaultStatus":"unknown"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L","baseScore":3.3,"baseSeverity":"LOW"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N","baseScore":4.8,"baseSeverity":"MEDIUM"}}],"problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-476","description":"CWE-476: NULL Pointer Dereference","type":"CWE"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-824889.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-959281.html"}]},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2024-37996","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"version":"2.0.3","timestamp":"2024-07-15T18:31:15.685735Z"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-08-27T20:42:54.503Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T04:04:24.762Z"},"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-824889.html","tags":["x_transferred"]}]}]}}