{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-37038","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","state":"PUBLISHED","assignerShortName":"schneider","dateReserved":"2024-05-31T06:52:05.762Z","datePublished":"2024-06-12T16:51:55.800Z","dateUpdated":"2024-08-02T03:43:50.738Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"Sage 1410","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Versions C3414-500-S02K5_P8 and prior"}]},{"defaultStatus":"unaffected","product":"Sage 1430","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Versions C3414-500-S02K5_P8 and prior"}]},{"defaultStatus":"unaffected","product":"Sage 1450","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Versions C3414-500-S02K5_P8 and prior"}]},{"defaultStatus":"unaffected","product":"Sage 2400","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Versions C3414-500-S02K5_P8 and prior"}]},{"defaultStatus":"unaffected","product":"Sage 3030 Magnum","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Versions C3414-500-S02K5_P8 and prior"}]},{"defaultStatus":"unaffected","product":"Sage 4400","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Versions C3414-500-S02K5_P8 and prior"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\n\n\n\n\n\n\nCWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated\nuser with access to the device’s web interface to perform unauthorized file and firmware\nuploads when crafting custom web requests.\n\n\n\n\n\n\n\n"}],"value":"CWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated\nuser with access to the device’s web interface to perform unauthorized file and firmware\nuploads when crafting custom web requests."}],"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-276","description":"CWE-276 Incorrect Default Permissions","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider","dateUpdated":"2024-06-12T16:51:55.800Z"},"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-163-05.pdf"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"affected":[{"vendor":"schneider_electric","product":"sage_4400","cpes":["cpe:2.3:h:schneider_electric:sage_4400:*:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"c3414-500-s02k5_p8","versionType":"custom"}]},{"vendor":"schneider_electric","product":"sage_1430","cpes":["cpe:2.3:h:schneider_electric:sage_1430:*:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"c3414-500-s02k5_p8","versionType":"custom"}]},{"vendor":"schneider_electric","product":"sage_2400","cpes":["cpe:2.3:h:schneider_electric:sage_2400:*:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"c3414-500-s02k5_p8","versionType":"custom"}]},{"vendor":"schneider_electric","product":"sage_3030m","cpes":["cpe:2.3:h:schneider_electric:sage_3030m:*:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"c3414-500-s02k5_p8","versionType":"custom"}]},{"vendor":"schneider_electric","product":"sage_1410","cpes":["cpe:2.3:h:schneider_electric:sage_1410:*:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"c3414-500-s02k5_p8","versionType":"custom"}]},{"vendor":"schneider_electric","product":"sage_1450","cpes":["cpe:2.3:h:schneider_electric:sage_1450:*:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"c3414-500-s02k5_p8","versionType":"custom"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-06-12T17:44:53.062764Z","id":"CVE-2024-37038","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-06-12T17:54:11.618Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T03:43:50.738Z"},"title":"CVE Program Container","references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-163-05.pdf","tags":["x_transferred"]}]}]}}