{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-37037","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","state":"PUBLISHED","assignerShortName":"schneider","dateReserved":"2024-05-31T06:52:05.762Z","datePublished":"2024-06-12T16:50:09.159Z","dateUpdated":"2024-08-02T03:43:50.902Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"Sage 1410","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Versions C3414-500-S02K5_P8 and prior"}]},{"defaultStatus":"unaffected","product":"Sage 1430","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Versions C3414-500-S02K5_P8 and prior"}]},{"defaultStatus":"unaffected","product":"Sage 1450","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Versions C3414-500-S02K5_P8 and prior"}]},{"defaultStatus":"unaffected","product":"Sage 2400","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Versions C3414-500-S02K5_P8 and prior"}]},{"defaultStatus":"unaffected","product":"Sage 3030 Magnum","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Versions C3414-500-S02K5_P8 and prior"}]},{"defaultStatus":"unaffected","product":"Sage 4400","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Versions C3414-500-S02K5_P8 and prior"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\n\n\n\n\nCWE-22: Improper Limitation of a Pathname to a Restricted Directory (‘Path\nTraversal’) vulnerability exists that could allow an authenticated user with access to the device’s\nweb interface to corrupt files and impact device functionality when sending a crafted HTTP\nrequest.\n\n\n\n\n\n"}],"value":"CWE-22: Improper Limitation of a Pathname to a Restricted Directory (‘Path\nTraversal’) vulnerability exists that could allow an authenticated user with access to the device’s\nweb interface to corrupt files and impact device functionality when sending a crafted HTTP\nrequest."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.1,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-22","description":"CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider","dateUpdated":"2024-06-12T16:50:09.159Z"},"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-163-05.pdf"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"affected":[{"vendor":"schneider-electric","product":"sage_4400","cpes":["cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*","cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*","cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*","cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*","cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*","cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"c3414-500-s02k5_p8","versionType":"custom"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-06-12T18:28:51.967522Z","id":"CVE-2024-37037","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-06-12T18:33:38.098Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T03:43:50.902Z"},"title":"CVE Program Container","references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-163-05.pdf","tags":["x_transferred"]}]}]}}