{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-33698","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","state":"PUBLISHED","assignerShortName":"siemens","dateReserved":"2024-04-26T12:32:09.263Z","datePublished":"2024-09-10T09:36:31.009Z","dateUpdated":"2025-10-14T09:15:00.448Z"},"containers":{"cna":{"providerMetadata":{"orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens","dateUpdated":"2025-10-14T09:15:00.448Z"},"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Opcenter Quality (All versions < V2406), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions), SINEMA Remote Connect Client (All versions < V3.2 SP3), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 5), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 3). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code."}],"affected":[{"vendor":"Siemens","product":"Opcenter Quality","versions":[{"status":"affected","version":"0","lessThan":"V2406","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Opcenter RDnL","versions":[{"status":"affected","version":"0","lessThan":"V2410","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS neo V4.0","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS neo V4.1","versions":[{"status":"affected","version":"0","lessThan":"V4.1 Update 2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS neo V5.0","versions":[{"status":"affected","version":"0","lessThan":"V5.0 Update 1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINEC NMS","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINEMA Remote Connect Client","versions":[{"status":"affected","version":"0","lessThan":"V3.2 SP3","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Totally Integrated Automation Portal (TIA Portal) V16","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Totally Integrated Automation Portal (TIA Portal) V17","versions":[{"status":"affected","version":"0","lessThan":"V17 Update 8","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Totally Integrated Automation Portal (TIA Portal) V18","versions":[{"status":"affected","version":"0","lessThan":"V18 Update 5","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Totally Integrated Automation Portal (TIA Portal) V19","versions":[{"status":"affected","version":"0","lessThan":"V19 Update 3","versionType":"custom"}],"defaultStatus":"unknown"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseScore":9.3,"baseSeverity":"CRITICAL"}}],"problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-122","description":"CWE-122: Heap-based Buffer Overflow","type":"CWE"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-039007.html"}]},"adp":[{"affected":[{"vendor":"siemens","product":"simatic_pcs_neo","cpes":["cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"4.0","status":"affected","lessThan":"4.1_update_2","versionType":"custom"}]},{"vendor":"siemens","product":"simatic_information_server","cpes":["cpe:2.3:a:siemens:totally_integrated_automation_portal:16:*:*:*:*:*:*:*","cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*","cpe:2.3:a:siemens:totally_integrated_automation_portal:19:*:*:*:*:*:*:*","cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:*","cpe:2.3:a:siemens:simatic_pcs_neo:5.0:*:*:*:*:*:*:*","cpe:2.3:a:siemens:simatic_information_server:2022:*:*:*:*:*:*:*","cpe:2.3:a:siemens:simatic_information_server:2024:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"siemens","product":"totally_integrated_automation_portal","cpes":["cpe:2.3:a:siemens:totally_integrated_automation_portal:17:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"17","status":"affected","lessThan":"17_update_8","versionType":"custom"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-09-10T17:32:07.999463Z","id":"CVE-2024-33698","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-09-10T18:26:36.889Z"}}]}}