{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-33583","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","state":"PUBLISHED","assignerShortName":"siemens","dateReserved":"2024-04-24T14:47:52.265Z","datePublished":"2024-05-14T10:03:06.924Z","dateUpdated":"2024-08-02T02:36:04.133Z"},"containers":{"cna":{"providerMetadata":{"orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens","dateUpdated":"2024-06-11T14:20:47.219Z"},"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected application contains a hidden configuration item to enable debug functionality. This could allow an authenticated local attacker to gain insight into the internal configuration of the deployment."}],"affected":[{"vendor":"Siemens","product":"SIMATIC RTLS Locating Manager","versions":[{"status":"affected","version":"0","lessThan":"V3.0.1.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC RTLS Locating Manager","versions":[{"status":"affected","version":"0","lessThan":"V3.0.1.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC RTLS Locating Manager","versions":[{"status":"affected","version":"0","lessThan":"V3.0.1.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC RTLS Locating Manager","versions":[{"status":"affected","version":"0","lessThan":"V3.0.1.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC RTLS Locating Manager","versions":[{"status":"affected","version":"0","lessThan":"V3.0.1.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC RTLS Locating Manager","versions":[{"status":"affected","version":"0","lessThan":"V3.0.1.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC RTLS Locating Manager","versions":[{"status":"affected","version":"0","lessThan":"V3.0.1.1","versionType":"custom"}],"defaultStatus":"unknown"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C","baseScore":3.3,"baseSeverity":"LOW"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","baseScore":4.8,"baseSeverity":"MEDIUM"}}],"problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-912","description":"CWE-912: Hidden Functionality","type":"CWE"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-093430.html"}]},"adp":[{"affected":[{"vendor":"siemens","product":"simatic_rtls_locating_manager","cpes":["cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"3.0.1.1","versionType":"custom"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-05-14T12:39:01.289567Z","id":"CVE-2024-33583","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-06-06T17:50:40.620Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T02:36:04.133Z"},"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-093430.html","tags":["x_transferred"]}]}]}}