{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-30189","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","state":"PUBLISHED","assignerShortName":"siemens","dateReserved":"2024-03-25T10:25:29.901Z","datePublished":"2024-04-09T08:34:40.217Z","dateUpdated":"2024-08-02T01:25:03.406Z"},"containers":{"cna":{"providerMetadata":{"orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens","dateUpdated":"2024-04-09T08:34:40.217Z"},"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0) (All versions), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0) (All versions), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0) (All versions), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0) (All versions), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0) (All versions), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0) (All versions), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6) (All versions), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0) (All versions), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6) (All versions), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0) (All versions), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0) (All versions), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0) (All versions), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0) (All versions), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0) (All versions), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0) (All versions), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0) (All versions), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0) (All versions), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0) (All versions), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0) (All versions), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0) (All versions), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6) (All versions), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0) (All versions), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0) (All versions), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6) (All versions), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0) (All versions), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0) (All versions), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0) (All versions), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0) (All versions), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0) (All versions), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0) (All versions), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0) (All versions), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0) (All versions), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0) (All versions), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0) (All versions), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0) (All versions), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0) (All versions), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0) (All versions), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0) (All versions), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0) (All versions), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0) (All versions), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0) (All versions), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0) (All versions), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0) (All versions), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0) (All versions), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0) (All versions), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0) (All versions), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0) (All versions), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0) (All versions), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) (All versions). This CVE refers to Scenario 1 \"Leak frames from the Wi-Fi queue\" of CVE-2022-47522.\r\n\r\nAffected devices queue frames in order to subsequently change the security context and leak the queued frames. This could allow a physically proximate attacker to intercept (possibly cleartext) target-destined frames."}],"affected":[{"vendor":"Siemens","product":"SCALANCE W721-1 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W721-1 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W722-1 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W722-1 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W722-1 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W734-1 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W734-1 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W734-1 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W734-1 RJ45 (USA)","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W738-1 M12","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W738-1 M12","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W748-1 M12","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W748-1 M12","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W748-1 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W748-1 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W761-1 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W761-1 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W774-1 M12 EEC","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W774-1 M12 EEC","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W774-1 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W774-1 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W774-1 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W774-1 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W774-1 RJ45 (USA)","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W778-1 M12","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W778-1 M12","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W778-1 M12 EEC","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W778-1 M12 EEC (USA)","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W786-1 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W786-1 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W786-2 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W786-2 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W786-2 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W786-2 SFP","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W786-2 SFP","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W786-2IA RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W786-2IA RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W788-1 M12","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W788-1 M12","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W788-1 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W788-1 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W788-2 M12","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W788-2 M12","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W788-2 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W788-2 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W788-2 RJ45","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:N/A:N","baseScore":6.1,"baseSeverity":"MEDIUM"}}],"problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-290","description":"CWE-290: Authentication Bypass by Spoofing","type":"CWE"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-457702.html"}]},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-07-29T16:06:10.437362Z","id":"CVE-2024-30189","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-07-29T16:06:26.152Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T01:25:03.406Z"},"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-457702.html","tags":["x_transferred"]}]}]}}