{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-2980","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","state":"PUBLISHED","assignerShortName":"VulDB","dateReserved":"2024-03-27T07:04:03.841Z","datePublished":"2024-03-27T14:31:03.946Z","dateUpdated":"2024-08-01T19:32:42.558Z"},"containers":{"cna":{"providerMetadata":{"orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","shortName":"VulDB","dateUpdated":"2024-03-27T14:31:03.946Z"},"title":"Tenda FH1202 execCommand formexeCommand stack-based overflow","problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-121","lang":"en","description":"CWE-121 Stack-based Buffer Overflow"}]}],"affected":[{"vendor":"Tenda","product":"FH1202","versions":[{"version":"1.2.0.14(408)","status":"affected"}]}],"descriptions":[{"lang":"en","value":"A vulnerability, which was classified as critical, has been found in Tenda FH1202 1.2.0.14(408). This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258149 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."},{"lang":"de","value":"Eine Schwachstelle wurde in Tenda FH1202 1.2.0.14(408) entdeckt. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion formexeCommand der Datei /goform/execCommand. Dank Manipulation des Arguments cmdinput mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff über das Netzwerk. Der Exploit steht zur öffentlichen Verfügung."}],"metrics":[{"cvssV3_1":{"version":"3.1","baseScore":8.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV3_0":{"version":"3.0","baseScore":8.8,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV2_0":{"version":"2.0","baseScore":9,"vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C"}}],"timeline":[{"time":"2024-03-27T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2024-03-27T01:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2024-03-27T08:10:15.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"wxhwxhwxh_tutu (VulDB User)","type":"reporter"}],"references":[{"url":"https://vuldb.com/?id.258149","name":"VDB-258149 | Tenda FH1202 execCommand formexeCommand stack-based overflow","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.258149","name":"VDB-258149 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.301270","name":"Submit #301270 | Tenda FH1202 V1.2.0.14(408) buffer overflow","tags":["third-party-advisory"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1202/formexeCommand.md","tags":["exploit"]}]},"adp":[{"affected":[{"vendor":"tenda","product":"fh1202_firmware","cpes":["cpe:2.3:o:tenda:fh1202_firmware:1.2.0.14\\(408\\):*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"1.2.0.14\\(408\\)","status":"affected"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-07-16T20:58:37.855774Z","id":"CVE-2024-2980","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-07-16T20:59:35.183Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-01T19:32:42.558Z"},"title":"CVE Program Container","references":[{"url":"https://vuldb.com/?id.258149","name":"VDB-258149 | Tenda FH1202 execCommand formexeCommand stack-based overflow","tags":["vdb-entry","technical-description","x_transferred"]},{"url":"https://vuldb.com/?ctiid.258149","name":"VDB-258149 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required","x_transferred"]},{"url":"https://vuldb.com/?submit.301270","name":"Submit #301270 | Tenda FH1202 V1.2.0.14(408) buffer overflow","tags":["third-party-advisory","x_transferred"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1202/formexeCommand.md","tags":["exploit","x_transferred"]}]}]}}