{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-29175","assignerOrgId":"c550e75a-17ff-4988-97f0-544cde3820fe","state":"PUBLISHED","assignerShortName":"dell","dateReserved":"2024-03-18T08:44:18.923Z","datePublished":"2024-06-26T03:03:06.155Z","dateUpdated":"2024-08-02T01:10:54.627Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"PowerProtect DD","vendor":"Dell","versions":[{"lessThanOrEqual":"7.13","status":"affected","version":"7.0","versionType":"semver"},{"lessThan":"2.7.7","status":"affected","version":"N/A","versionType":"semver"},{"lessThan":"5.16.0.0","status":"affected","version":"N/A","versionType":"semver"},{"lessThanOrEqual":"7.13","status":"affected","version":"7.8","versionType":"semver"}]}],"datePublic":"2024-06-24T06:30:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Dell PowerProtect Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contain an weak cryptographic algorithm vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to man-in-the-middle attack that exposes sensitive session information."}],"value":"Dell PowerProtect Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contain an weak cryptographic algorithm vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to man-in-the-middle attack that exposes sensitive session information."}],"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":5.9,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-327","description":"CWE-327: Use of a Broken or Risky Cryptographic Algorithm","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"c550e75a-17ff-4988-97f0-544cde3820fe","shortName":"dell","dateUpdated":"2024-06-26T03:03:06.155Z"},"references":[{"tags":["vendor-advisory"],"url":"https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"affected":[{"vendor":"dell","product":"powerprotect_dd","cpes":["cpe:2.3:h:dell:powerprotect_dd:*:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","versions":[{"version":"7.0","status":"affected","lessThanOrEqual":"7.13","versionType":"semver"},{"version":"0","status":"affected","lessThan":"2.7.7","versionType":"semver"},{"version":"0","status":"affected","lessThan":"5.16.0.0","versionType":"semver"},{"version":"7.8","status":"affected","lessThanOrEqual":"7.13","versionType":"semver"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-07-11T15:11:41.076013Z","id":"CVE-2024-29175","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-07-11T15:17:48.750Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T01:10:54.627Z"},"title":"CVE Program Container","references":[{"tags":["vendor-advisory","x_transferred"],"url":"https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"}]}]}}