{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-28171","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","state":"PUBLISHED","assignerShortName":"icscert","dateReserved":"2024-03-12T15:07:02.588Z","datePublished":"2024-03-21T22:19:36.480Z","dateUpdated":"2024-08-28T14:18:49.656Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"DIAEnergie","vendor":"Delta Electronics","versions":[{"lessThan":"v1.10.00.005","status":"affected","version":"0","versionType":"custom"}]}],"credits":[{"lang":"en","type":"finder","value":"Michael Heinzl reported these vulnerabilities to CISA."}],"datePublic":"2024-03-14T17:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\n<span style=\"background-color: rgb(255, 255, 255);\">It is possible to perform a path traversal attack and write outside of the intended directory. If a file name is specified that already exists on the file system, then the original file will be overwritten.</span>\n\n"}],"value":"\nIt is possible to perform a path traversal attack and write outside of the intended directory. If a file name is specified that already exists on the file system, then the original file will be overwritten.\n\n"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.1,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-22","description":"CWE-22: Improper limitation of a pathname to a restricted directory ('Path traversal')","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert","dateUpdated":"2024-03-21T22:19:36.480Z"},"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-12"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\n<span style=\"background-color: rgb(255, 255, 255);\">Delta recommends users update to DIAEnergie v1.10.00.005. Users can request this version of DIAEnergie from </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://www.deltaww.com/en/customerService\">Delta Electronics' regional sales or agents</a><span style=\"background-color: rgb(255, 255, 255);\">.</span>\n\n<br>"}],"value":"\nDelta recommends users update to DIAEnergie v1.10.00.005. Users can request this version of DIAEnergie from  Delta Electronics' regional sales or agents https://www.deltaww.com/en/customerService .\n\n"}],"source":{"advisory":"ICSA-24-074-12","discovery":"EXTERNAL"},"title":"Delta Electronics DIAEnergie Path traversal","x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T00:48:49.142Z"},"title":"CVE Program Container","references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-12","tags":["x_transferred"]}]},{"affected":[{"vendor":"delta_electronics","product":"diaenergie","cpes":["cpe:2.3:a:delta_electronics:diaenergie:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"v1.10.00.005","versionType":"custom"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-03-22T17:56:00.396002Z","id":"CVE-2024-28171","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-08-28T14:18:49.656Z"}}]}}