{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-28045","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","state":"PUBLISHED","assignerShortName":"icscert","dateReserved":"2024-03-12T15:07:02.565Z","datePublished":"2024-03-21T22:24:12.286Z","dateUpdated":"2024-08-02T00:48:47.822Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"DIAEnergie","vendor":"Delta Electronics","versions":[{"lessThan":"v1.10.00.005","status":"affected","version":"0","versionType":"custom"}]}],"credits":[{"lang":"en","type":"finder","value":"Michael Heinzl reported these vulnerabilities to CISA."}],"datePublic":"2024-03-14T17:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\n<span style=\"background-color: rgb(255, 255, 255);\">Improper neutralization of input within the affected product could lead to cross-site scripting.</span>\n\n"}],"value":"\nImproper neutralization of input within the affected product could lead to cross-site scripting.\n\n"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":4.6,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-79","description":"CWE-79: Improper neutralization of input during web page generation ('Cross-site scripting')","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert","dateUpdated":"2024-03-21T22:24:12.286Z"},"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-12"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\n<span style=\"background-color: rgb(255, 255, 255);\">Delta recommends users update to DIAEnergie v1.10.00.005. Users can request this version of DIAEnergie from </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://www.deltaww.com/en/customerService\">Delta Electronics' regional sales or agents</a><span style=\"background-color: rgb(255, 255, 255);\">.</span>\n\n<br>"}],"value":"\nDelta recommends users update to DIAEnergie v1.10.00.005. Users can request this version of DIAEnergie from  Delta Electronics' regional sales or agents https://www.deltaww.com/en/customerService .\n\n"}],"source":{"advisory":"ICSA-24-074-12","discovery":"EXTERNAL"},"title":"Delta Electronics DIAEnergie Cross-site scripting","x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2024-28045","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"version":"2.0.3","timestamp":"2024-03-27T14:14:37.320637Z"}}}],"providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-06-04T18:04:05.637Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T00:48:47.822Z"},"title":"CVE Program Container","references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-12","tags":["x_transferred"]}]}]}}