{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-26276","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","state":"PUBLISHED","assignerShortName":"siemens","dateReserved":"2024-02-15T10:54:03.168Z","datePublished":"2024-04-09T08:34:37.744Z","dateUpdated":"2024-08-13T07:54:02.376Z"},"containers":{"cna":{"providerMetadata":{"orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens","dateUpdated":"2024-08-13T07:54:02.376Z"},"descriptions":[{"lang":"en","value":"A vulnerability has been identified in JT2Go (All versions < V2312.0004), Parasolid V35.1 (All versions < V35.1.254), Parasolid V36.0 (All versions < V36.0.207), Parasolid V36.1 (All versions < V36.1.147), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition."}],"affected":[{"vendor":"Siemens","product":"JT2Go","versions":[{"status":"affected","version":"0","lessThan":"V2312.0004","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Parasolid V35.1","versions":[{"status":"affected","version":"0","lessThan":"V35.1.254","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Parasolid V36.0","versions":[{"status":"affected","version":"0","lessThan":"V36.0.207","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Parasolid V36.1","versions":[{"status":"affected","version":"0","lessThan":"V36.1.147","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Teamcenter Visualization V14.2","versions":[{"status":"affected","version":"0","lessThan":"V14.2.0.12","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Teamcenter Visualization V14.3","versions":[{"status":"affected","version":"0","lessThan":"V14.3.0.9","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Teamcenter Visualization V2312","versions":[{"status":"affected","version":"0","lessThan":"V2312.0004","versionType":"custom"}],"defaultStatus":"unknown"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L","baseScore":3.3,"baseSeverity":"LOW"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N","baseScore":4.8,"baseSeverity":"MEDIUM"}}],"problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-770","description":"CWE-770: Allocation of Resources Without Limits or Throttling","type":"CWE"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-222019.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-771940.html"}]},"adp":[{"affected":[{"vendor":"siemens","product":"parasolid","cpes":["cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"35.1","status":"affected","lessThan":"35.1.254","versionType":"custom"}]},{"vendor":"siemens","product":"parasolid","cpes":["cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"36.0","status":"affected","lessThan":"36.0.207","versionType":"custom"}]},{"vendor":"siemens","product":"parasolid","cpes":["cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"36.1","status":"affected","lessThan":"36.1.147","versionType":"custom"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-05-14T13:40:25.505191Z","id":"CVE-2024-26276","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-06-06T14:53:58.636Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T00:07:18.871Z"},"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-222019.html","tags":["x_transferred"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-771940.html","tags":["x_transferred"]}]}]}}