{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-2559","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","state":"PUBLISHED","assignerShortName":"VulDB","dateReserved":"2024-03-16T06:54:29.196Z","datePublished":"2024-03-17T09:31:04.514Z","dateUpdated":"2024-08-01T19:18:46.983Z"},"containers":{"cna":{"providerMetadata":{"orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","shortName":"VulDB","dateUpdated":"2024-03-17T09:31:04.514Z"},"title":"Tenda AC18 SysToolReboot fromSysToolReboot cross-site request forgery","problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-352","lang":"en","description":"CWE-352 Cross-Site Request Forgery"}]}],"affected":[{"vendor":"Tenda","product":"AC18","versions":[{"version":"15.03.05.05","status":"affected"}]}],"descriptions":[{"lang":"en","value":"A vulnerability classified as problematic has been found in Tenda AC18 15.03.05.05. Affected is the function fromSysToolReboot of the file /goform/SysToolReboot. The manipulation leads to cross-site request forgery. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257058 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."},{"lang":"de","value":"Es wurde eine problematische Schwachstelle in Tenda AC18 15.03.05.05 entdeckt. Dabei betrifft es die Funktion fromSysToolReboot der Datei /goform/SysToolReboot. Durch Beeinflussen mit unbekannten Daten kann eine cross-site request forgery-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei über das Netzwerk erfolgen. Der Exploit steht zur öffentlichen Verfügung."}],"metrics":[{"cvssV3_1":{"version":"3.1","baseScore":4.3,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N","baseSeverity":"MEDIUM"}},{"cvssV3_0":{"version":"3.0","baseScore":4.3,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N","baseSeverity":"MEDIUM"}},{"cvssV2_0":{"version":"2.0","baseScore":5,"vectorString":"AV:N/AC:L/Au:N/C:N/I:P/A:N"}}],"timeline":[{"time":"2024-03-16T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2024-03-16T01:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2024-03-16T07:59:38.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"yhryhryhr_backup (VulDB User)","type":"reporter"}],"references":[{"url":"https://vuldb.com/?id.257058","name":"VDB-257058 | Tenda AC18 SysToolReboot fromSysToolReboot cross-site request forgery","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.257058","name":"VDB-257058 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/fromSysToolReboot.md","tags":["exploit"]}]},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2024-2559","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"version":"2.0.3","timestamp":"2024-03-18T18:45:25.675349Z"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-07-05T17:22:21.132Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-01T19:18:46.983Z"},"title":"CVE Program Container","references":[{"url":"https://vuldb.com/?id.257058","name":"VDB-257058 | Tenda AC18 SysToolReboot fromSysToolReboot cross-site request forgery","tags":["vdb-entry","technical-description","x_transferred"]},{"url":"https://vuldb.com/?ctiid.257058","name":"VDB-257058 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required","x_transferred"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/fromSysToolReboot.md","tags":["exploit","x_transferred"]}]}]}}