{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-23971","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","state":"PUBLISHED","assignerShortName":"icscert","dateReserved":"2024-01-25T00:14:42.599Z","datePublished":"2025-01-30T23:42:57.796Z","dateUpdated":"2025-08-26T21:08:23.253Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"Home Flex","vendor":"ChargePoint","versions":[{"status":"affected","version":"all versions","versionType":"semver"}]}],"credits":[{"lang":"en","type":"finder","value":"Daan Keuper, Thijs Alkemade and Khaled Nassar from Computest Sector 7 reported to ZDI."}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex charging stations. Authentication is not required to exploit this vulnerability.</p><p>The specific flaw exists within the handling of OCPP messages. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root.</p>"}],"value":"This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex charging stations. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of OCPP messages. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-77","description":"CWE-77","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert","dateUpdated":"2025-06-30T17:43:13.112Z"},"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-24-1053/"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"The vendor states this vulnerability was patched in April 2024.\n\n<br>"}],"value":"The vendor states this vulnerability was patched in April 2024."}],"source":{"discovery":"EXTERNAL"},"title":"ChargePoint Home Flex OCPP bswitch Command Injection","x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"metrics":[{"cvssV3_1":{"scope":"UNCHANGED","version":"3.1","baseScore":8.8,"attackVector":"ADJACENT_NETWORK","baseSeverity":"HIGH","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","integrityImpact":"HIGH","userInteraction":"NONE","attackComplexity":"LOW","availabilityImpact":"HIGH","privilegesRequired":"NONE","confidentialityImpact":"HIGH"}},{"other":{"type":"ssvc","content":{"id":"CVE-2024-23971","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"version":"2.0.3","timestamp":"2025-01-31T19:03:57.963147Z"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-08-26T21:08:23.253Z"}}]}}