{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-2052","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","state":"PUBLISHED","assignerShortName":"schneider","dateReserved":"2024-03-01T01:26:10.084Z","datePublished":"2024-03-18T16:05:47.722Z","dateUpdated":"2024-08-15T16:23:48.504Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"Easergy T200 (Modbus) Models: T200I, T200E, T200P, T200S, T200H ","vendor":"Schneider Electric","versions":[{"lessThanOrEqual":"prior","status":"affected","version":"SC2-04MOD-07000104","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Easergy T200 (IEC104) Models: T200I, T200E, T200P, T200S, T200H","vendor":"Schneider Electric ","versions":[{"lessThanOrEqual":"prior","status":"affected","version":"SC2-04IEC-07000104","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Easergy T200 (DNP3) Models: T200I, T200E, T200P, T200S, T200H","vendor":"Schneider Electric ","versions":[{"lessThanOrEqual":"prior","status":"affected","version":"SC2-04DNP-07000104","versionType":"custom"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\n\n\n\n\nCWE-552: Files or Directories Accessible to External Parties vulnerability exists that could allow\nunauthenticated files and logs exfiltration and download of files when an attacker modifies the\nURL to download to a different location.\n\n\n\n\n\n"}],"value":"\nCWE-552: Files or Directories Accessible to External Parties vulnerability exists that could allow\nunauthenticated files and logs exfiltration and download of files when an attacker modifies the\nURL to download to a different location.\n\n"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-552","description":"CWE-552 Files or Directories Accessible to External Parties","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider","dateUpdated":"2024-03-18T16:05:47.722Z"},"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-072-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-072-01.pdf"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-01T19:03:37.849Z"},"title":"CVE Program Container","references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-072-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-072-01.pdf","tags":["x_transferred"]}]},{"affected":[{"vendor":"schneider-electric","product":"t200i","cpes":["cpe:2.3:h:schneider-electric:t200h:-:*:*:*:*:*:*:*","cpe:2.3:h:schneider-electric:t200s:-:*:*:*:*:*:*:*","cpe:2.3:h:schneider-electric:t200p:-:*:*:*:*:*:*:*","cpe:2.3:h:schneider-electric:t200e:-:*:*:*:*:*:*:*","cpe:2.3:h:schneider-electric:t200i:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"sc2-04mod-07000104","versionType":"custom"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-03-18T18:25:55.996825Z","id":"CVE-2024-2052","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-08-15T16:23:48.504Z"}}]}}