{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-1914","assignerOrgId":"2b718523-d88f-4f37-9bbd-300c20644bf9","state":"PUBLISHED","assignerShortName":"ABB","dateReserved":"2024-02-27T02:10:19.053Z","datePublished":"2024-05-14T13:41:02.136Z","dateUpdated":"2024-08-01T18:56:22.492Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","platforms":["IRC5"],"product":"RobotWare 6","vendor":"ABB","versions":[{"lessThan":"6.15.06 except 6.10.10 and 6.13.07 ","status":"affected","version":"6.0.0","versionType":"custom"}]},{"defaultStatus":"unaffected","platforms":["OmniCore"],"product":"RobotWare 7","vendor":"ABB","versions":[{"lessThan":"7.14","status":"affected","version":"7.0","versionType":"custom"}]}],"credits":[{"lang":"en","type":"finder","value":"ABB thanks Yuncheng Wang, Institute of Information Engineering, Chinese Academy of Sciences; School  of Cyber Security, University of Chinese Academy of Sciences, Beijing, China for responsibly reporting  the vulnerabilities and working with us as we addressed them."}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"An attacker who successfully exploited these vulnerabilities could cause the robot to stop, make the robot controller inaccessible.  <br><br>The vulnerability could potentially be exploited to perform unauthorized actions by an attacker. This vulnerability arises under specific condition when specially crafted message is processed by the system. <br><br>Below are reported vulnerabilities in the Robot Ware versions. <br><br>* IRC5- RobotWare 6 &lt; 6.15.06 except 6.10.10, and 6.13.07 <br>* OmniCore- RobotWare 7 &lt; 7.14"}],"value":"An attacker who successfully exploited these vulnerabilities could cause the robot to stop, make the robot controller inaccessible.  \n\nThe vulnerability could potentially be exploited to perform unauthorized actions by an attacker. This vulnerability arises under specific condition when specially crafted message is processed by the system. \n\nBelow are reported vulnerabilities in the Robot Ware versions. \n\n* IRC5- RobotWare 6 < 6.15.06 except 6.10.10, and 6.13.07 \n* OmniCore- RobotWare 7 < 7.14"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-476","description":"CWE-476 NULL Pointer Dereference","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"2b718523-d88f-4f37-9bbd-300c20644bf9","shortName":"ABB","dateUpdated":"2024-05-14T16:10:23.298Z"},"references":[{"url":"https://search.abb.com/library/Download.aspx?DocumentID=SI20330&LanguageCode=en&DocumentPartId=&Action=Launch"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"affected":[{"vendor":"abb","product":"robotware","cpes":["cpe:2.3:a:abb:robotware:6.0.0:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","versions":[{"version":"6.0.0","status":"affected","lessThan":"6.15.06","versionType":"custom"},{"version":"6.10.10","status":"unaffected"},{"version":"6.13.07","status":"unaffected"}]},{"vendor":"abb","product":"robotware","cpes":["cpe:2.3:a:abb:robotware:7.0:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","versions":[{"version":"7.0","status":"affected","lessThan":"7.14","versionType":"custom"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-05-14T15:06:59.720219Z","id":"CVE-2024-1914","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-06-06T13:17:40.400Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-01T18:56:22.492Z"},"title":"CVE Program Container","references":[{"url":"https://search.abb.com/library/Download.aspx?DocumentID=SI20330&LanguageCode=en&DocumentPartId=&Action=Launch","tags":["x_transferred"]}]}]}}