{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-12169","assignerOrgId":"e383dce4-0c27-4495-91c4-0db157728d17","state":"PUBLISHED","assignerShortName":"Hitachi Energy","dateReserved":"2024-12-04T15:01:44.851Z","datePublished":"2025-03-25T12:36:02.457Z","dateUpdated":"2025-03-25T13:11:20.584Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"RTU500","vendor":"Hitachi Energy","versions":[{"lessThanOrEqual":"13.4.4","status":"affected","version":"13.4.1","versionType":"custom"},{"lessThanOrEqual":"13.5.3","status":"affected","version":"13.5.1","versionType":"custom"},{"status":"affected","version":"13.6.1","versionType":"custom"},{"lessThanOrEqual":"13.7.4","status":"affected","version":"13.7.1","versionType":"custom"},{"status":"unaffected","version":"13.7.6","versionType":"custom"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"A vulnerability exists in RTU500 IEC 60870-5-104 controlled station functionality and IEC 61850 functionality, that allows an attacker performing a specific attack sequence to restart the affected CMU. This vulnerability only applies, if secure communication using IEC 62351-3 (TLS) is enabled."}],"value":"A vulnerability exists in RTU500 IEC 60870-5-104 controlled station functionality and IEC 61850 functionality, that allows an attacker performing a specific attack sequence to restart the affected CMU. This vulnerability only applies, if secure communication using IEC 62351-3 (TLS) is enabled."}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"AUTOMATIC","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":8.7,"baseSeverity":"HIGH","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/R:A","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"description":"CWE:410 Insufficient Resource Pool","lang":"en"}]}],"providerMetadata":{"orgId":"e383dce4-0c27-4495-91c4-0db157728d17","shortName":"Hitachi Energy","dateUpdated":"2025-03-25T12:36:02.457Z"},"references":[{"url":"https://publisher.hitachienergy.com/preview?DocumentId=8DBD000207&languageCode=en&Preview=true"}],"source":{"discovery":"INTERNAL"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-03-25T13:11:12.407607Z","id":"CVE-2024-12169","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-03-25T13:11:20.584Z"}}]}}