{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-11061","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","state":"PUBLISHED","assignerShortName":"VulDB","dateReserved":"2024-11-10T08:45:18.006Z","datePublished":"2024-11-11T00:31:07.099Z","dateUpdated":"2024-11-12T18:27:42.336Z"},"containers":{"cna":{"providerMetadata":{"orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","shortName":"VulDB","dateUpdated":"2024-11-11T00:31:07.099Z"},"title":"Tenda AC10 fast_setting_wifi_set FUN_0044db3c stack-based overflow","problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-121","lang":"en","description":"Stack-based Buffer Overflow"}]},{"descriptions":[{"type":"CWE","cweId":"CWE-119","lang":"en","description":"Memory Corruption"}]}],"affected":[{"vendor":"Tenda","product":"AC10","versions":[{"version":"16.03.10.13","status":"affected"}]}],"descriptions":[{"lang":"en","value":"A vulnerability classified as critical was found in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function FUN_0044db3c of the file /goform/fast_setting_wifi_set. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."},{"lang":"de","value":"In Tenda AC10 16.03.10.13 wurde eine kritische Schwachstelle entdeckt. Betroffen ist die Funktion FUN_0044db3c der Datei /goform/fast_setting_wifi_set. Durch das Manipulieren des Arguments timeZone mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann über das Netzwerk passieren. Der Exploit steht zur öffentlichen Verfügung."}],"metrics":[{"cvssV4_0":{"version":"4.0","baseScore":8.7,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseSeverity":"HIGH"}},{"cvssV3_1":{"version":"3.1","baseScore":8.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV3_0":{"version":"3.0","baseScore":8.8,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV2_0":{"version":"2.0","baseScore":9,"vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C"}}],"timeline":[{"time":"2024-11-10T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2024-11-10T01:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2024-11-10T09:50:30.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"hand_king (VulDB User)","type":"reporter"}],"references":[{"url":"https://vuldb.com/?id.283807","name":"VDB-283807 | Tenda AC10 fast_setting_wifi_set FUN_0044db3c stack-based overflow","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.283807","name":"VDB-283807 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.440825","name":"Submit #440825 | Tenda AC10v4 V16.03.10.13 Stack-based Buffer Overflow","tags":["third-party-advisory"]},{"url":"https://tasty-foxtrot-3a8.notion.site/Tenda-AC10v4-FUN_0044db3c-stack-overflow-13a0448e619580ae96fee2899545e159","tags":["exploit"]},{"url":"https://www.tenda.com.cn/","tags":["product"]}]},"adp":[{"affected":[{"vendor":"tenda","product":"ac10_firmware","cpes":["cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"16.03.10.13","status":"affected"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-11-12T16:17:31.059883Z","id":"CVE-2024-11061","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-11-12T18:27:42.336Z"}}]}}