{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-10575","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","state":"PUBLISHED","assignerShortName":"schneider","dateReserved":"2024-10-31T08:33:14.823Z","datePublished":"2024-11-13T04:35:44.556Z","dateUpdated":"2024-11-13T15:14:17.114Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"EcoStruxure IT Gateway","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 1.21.0.6"},{"status":"affected","version":"Version 1.22.0.3"},{"status":"affected","version":"Version 1.22.1.5"},{"status":"affected","version":"Version 1.23.0.4"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"CWE-862: Missing Authorization vulnerability exists that could cause unauthorized access when enabled on\nthe network and potentially impacting connected devices."}],"value":"CWE-862: Missing Authorization vulnerability exists that could cause unauthorized access when enabled on\nthe network and potentially impacting connected devices."}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":10,"baseSeverity":"CRITICAL","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"HIGH","subConfidentialityImpact":"HIGH","subIntegrityImpact":"LOW","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-862","description":"CWE-862 Missing Authorization","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider","dateUpdated":"2024-11-13T04:35:44.556Z"},"references":[{"url":"https://download.schneider-electric.com/doc/SEVD-2024-317-04/SEVD-2024-317-04.pdf"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"affected":[{"vendor":"schneider-electric","product":"ecostruxure_it_gateway","cpes":["cpe:2.3:a:schneider-electric:ecostruxure_it_gateway:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"1.21.0.6","status":"affected"},{"version":"1.22.0.3","status":"affected"},{"version":"1.22.1.5","status":"affected"},{"version":"1.23.0.4","status":"affected"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-11-13T15:14:10.869591Z","id":"CVE-2024-10575","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-11-13T15:14:17.114Z"}}]}}