{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-10123","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","state":"PUBLISHED","assignerShortName":"VulDB","dateReserved":"2024-10-18T12:13:59.942Z","datePublished":"2024-10-18T19:31:05.643Z","dateUpdated":"2024-10-18T20:42:45.158Z"},"containers":{"cna":{"providerMetadata":{"orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","shortName":"VulDB","dateUpdated":"2024-10-18T19:31:05.643Z"},"title":"Tenda AC8 saveParentControlInfo compare_parentcontrol_time stack-based overflow","problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-121","lang":"en","description":"Stack-based Buffer Overflow"}]}],"affected":[{"vendor":"Tenda","product":"AC8","versions":[{"version":"16.03.34.06","status":"affected"}]}],"descriptions":[{"lang":"en","value":"A vulnerability was found in Tenda AC8 16.03.34.06. It has been declared as critical. Affected by this vulnerability is the function compare_parentcontrol_time of the file /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This is not the same issue like CVE-2023-33671. The vendor was contacted early about this disclosure but did not respond in any way."},{"lang":"de","value":"In Tenda AC8 16.03.34.06 wurde eine kritische Schwachstelle ausgemacht. Es geht um die Funktion compare_parentcontrol_time der Datei /goform/saveParentControlInfo. Durch Manipulieren des Arguments time mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann über das Netzwerk erfolgen. Der Exploit steht zur öffentlichen Verfügung."}],"metrics":[{"cvssV4_0":{"version":"4.0","baseScore":8.7,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseSeverity":"HIGH"}},{"cvssV3_1":{"version":"3.1","baseScore":8.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV3_0":{"version":"3.0","baseScore":8.8,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV2_0":{"version":"2.0","baseScore":9,"vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C"}}],"timeline":[{"time":"2024-10-18T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2024-10-18T02:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2024-10-18T14:19:53.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"minipython (VulDB User)","type":"reporter"}],"references":[{"url":"https://vuldb.com/?id.280915","name":"VDB-280915 | Tenda AC8 saveParentControlInfo compare_parentcontrol_time stack-based overflow","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.280915","name":"VDB-280915 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.421340","name":"Submit #421340 | Tenda AC8v4 V16.03.34.06 Stack-based Buffer Overflow","tags":["third-party-advisory"]},{"url":"https://github.com/JohenanLi/router_vuls/blob/main/ac8v4/compare_parentcontrol_time_vul.md","tags":["exploit"]},{"url":"https://www.tenda.com.cn/","tags":["product"]}]},"adp":[{"affected":[{"vendor":"tenda","product":"ac8_firmware","cpes":["cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"16.03.34.06","status":"affected"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-10-18T20:42:10.984477Z","id":"CVE-2024-10123","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-10-18T20:42:45.158Z"}}]}}