{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-6943","assignerOrgId":"e0f77b61-78fd-4786-b3fb-1ee347a748ad","state":"PUBLISHED","assignerShortName":"Mitsubishi","dateReserved":"2023-12-19T08:00:07.140Z","datePublished":"2024-01-30T09:09:29.248Z","dateUpdated":"2025-09-19T02:13:47.115Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"EZSocket","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"3.0 to 5.92"}]},{"defaultStatus":"unaffected","product":"GT Designer3 Version1(GOT1000)","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"1.325P and prior"}]},{"defaultStatus":"unaffected","product":"GT Designer3 Version1(GOT2000)","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"1.320J and prior"}]},{"defaultStatus":"unaffected","product":"GX Works2","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"1.11M to 1.626C"}]},{"defaultStatus":"unaffected","product":"GX Works3","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"1.106L and prior"}]},{"defaultStatus":"unaffected","product":"MELSOFT Navigator","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"1.04E to 2.102G"}]},{"defaultStatus":"unaffected","product":"MT Works2","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"1.190Y and prior"}]},{"defaultStatus":"unaffected","product":"MX Component","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"4.00A to 5.007H"}]},{"defaultStatus":"unaffected","product":"MX OPC Server DA/UA","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"all versions"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M to 1.626C, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E to 2.102G, MT Works2 versions 1.190Y and prior, MX Component versions 4.00A to 5.007H and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products."}],"value":"Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M to 1.626C, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E to 2.102G, MT Works2 versions 1.190Y and prior, MX Component versions 4.00A to 5.007H and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products."}],"impacts":[{"descriptions":[{"lang":"en","value":"Remote Code Execution"}]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-470","description":"CWE-470 Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"e0f77b61-78fd-4786-b3fb-1ee347a748ad","shortName":"Mitsubishi","dateUpdated":"2025-09-19T02:13:47.115Z"},"references":[{"tags":["vendor-advisory"],"url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf"},{"tags":["government-resource"],"url":"https://jvn.jp/vu/JVNVU95103362"},{"tags":["government-resource"],"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T08:42:08.552Z"},"title":"CVE Program Container","references":[{"tags":["vendor-advisory","x_transferred"],"url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf"},{"tags":["government-resource","x_transferred"],"url":"https://jvn.jp/vu/JVNVU95103362"},{"tags":["government-resource","x_transferred"],"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02"}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-02-06T05:00:32.912521Z","id":"CVE-2023-6943","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-05-30T19:01:43.512Z"}}]}}