{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-6815","assignerOrgId":"e0f77b61-78fd-4786-b3fb-1ee347a748ad","state":"PUBLISHED","assignerShortName":"Mitsubishi","dateReserved":"2023-12-14T02:59:09.887Z","datePublished":"2024-02-13T06:27:51.202Z","dateUpdated":"2024-08-02T08:42:07.419Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"MELSEC iQ-R Series Safety CPU R08SFCPU","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"all versions"}]},{"defaultStatus":"unaffected","product":"MELSEC iQ-R Series Safety CPU R16SFCPU","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"all versions"}]},{"defaultStatus":"unaffected","product":"MELSEC iQ-R Series Safety CPU R32SFCPU","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"all versions"}]},{"defaultStatus":"unaffected","product":"MELSEC iQ-R Series Safety CPU R120SFCPU","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"all versions"}]},{"defaultStatus":"unaffected","product":"MELSEC iQ-R Series SIL2 Process CPU R08PSFCPU","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"all versions"}]},{"defaultStatus":"unaffected","product":"MELSEC iQ-R Series SIL2 Process CPU R16PSFCPU","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"all versions"}]},{"defaultStatus":"unaffected","product":"MELSEC iQ-R Series SIL2 Process CPU R32PSFCPU","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"all versions"}]},{"defaultStatus":"unaffected","product":"MELSEC iQ-R Series SIL2 Process CPU R120PSFCPU","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"all versions"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Incorrect Privilege Assignment vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series Safety CPU R08/16/32/120SFCPU all versions and MELSEC iQ-R Series SIL2 Process CPU R08/16/32/120PSFCPU all versions allows a remote authenticated attacker who has logged into the product as a non-administrator user to disclose the credentials (user ID and password) of a user with a lower access level than the attacker by sending a specially crafted packet."}],"value":"Incorrect Privilege Assignment vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series Safety CPU R08/16/32/120SFCPU all versions and MELSEC iQ-R Series SIL2 Process CPU R08/16/32/120PSFCPU all versions allows a remote authenticated attacker who has logged into the product as a non-administrator user to disclose the credentials (user ID and password) of a user with a lower access level than the attacker by sending a specially crafted packet."}],"impacts":[{"descriptions":[{"lang":"en","value":"Information Disclosure"}]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-266","description":"CWE-266 Incorrect Privilege Assignment","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"e0f77b61-78fd-4786-b3fb-1ee347a748ad","shortName":"Mitsubishi","dateUpdated":"2024-02-14T03:59:42.705Z"},"references":[{"tags":["vendor-advisory"],"url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-021_en.pdf"},{"tags":["government-resource"],"url":"https://jvn.jp/vu/JVNVU95085830/index.html"},{"tags":["government-resource"],"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-044-01"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2023-6815","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"version":"2.0.3","timestamp":"2024-02-13T16:44:26.588675Z"}}}],"providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-06-04T17:17:01.365Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T08:42:07.419Z"},"title":"CVE Program Container","references":[{"tags":["vendor-advisory","x_transferred"],"url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-021_en.pdf"},{"tags":["government-resource","x_transferred"],"url":"https://jvn.jp/vu/JVNVU95085830/index.html"},{"tags":["government-resource","x_transferred"],"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-044-01"}]}]}}