{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-5986","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","state":"PUBLISHED","assignerShortName":"schneider","dateReserved":"2023-11-07T10:57:54.715Z","datePublished":"2023-11-15T03:47:17.684Z","dateUpdated":"2024-12-02T21:11:40.870Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"EcoStruxure Power Monitoring Expert (PME)","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 2020 CU2 and prior"},{"status":"affected","version":"Version 2021 CU1 and prior"}]},{"defaultStatus":"unaffected","product":"EcoStruxure Power Operation (EPO) – Advanced Reporting and Dashboards Module","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Advanced Reporting and Dashboards Module 2021 prior to CU2 for EcoStruxure Power Operation 2021"},{"status":"affected","version":"Advanced Reporting and Dashboards Module 2020 prior to CU3"}]},{"defaultStatus":"unaffected","product":"EcoStruxure Power SCADA Operation (PSO) - Advanced Reporting and Dashboards Module","vendor":"Schneider Electric","versions":[{"status":"affected","version":"EcoStruxure Power SCADA Operation (PSO) 2020 or 2020 R2"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\nA CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input\nattackers can cause the software’s web application to redirect to the chosen domain after a\nsuccessful login is performed. \n\n\n"}],"value":"\nA CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input\nattackers can cause the software’s web application to redirect to the chosen domain after a\nsuccessful login is performed. \n\n\n"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":8.2,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-601","description":"CWE-601 URL Redirection to Untrusted Site ('Open Redirect')","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider","dateUpdated":"2023-11-15T03:47:17.684Z"},"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-02.pdf"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T08:14:25.141Z"},"title":"CVE Program Container","references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-02.pdf","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2023-11-30T19:15:01.048115Z","id":"CVE-2023-5986","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-12-02T21:11:40.870Z"}}]}}