{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-5393","assignerOrgId":"0dc86260-d7e3-4e81-ba06-3508e030ce8d","state":"PUBLISHED","assignerShortName":"Honeywell","dateReserved":"2023-10-04T17:50:46.496Z","datePublished":"2024-04-11T19:20:20.553Z","dateUpdated":"2024-08-02T07:59:44.301Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","platforms":["Experion PKS"],"product":"Experion Server","vendor":"Honeywell","versions":[{"lessThan":"520.2 TCU4","status":"unaffected","version":"520.2","versionType":"semver"},{"lessThan":"510.2 HF13","status":"unaffected","version":"510.1","versionType":"semver"},{"lessThan":"520.1 TCU4","status":"unaffected","version":"520.1","versionType":"semver"},{"lessThan":"511.5 TCU4 HF3","status":"unaffected","version":"511.1","versionType":"semver"}]},{"defaultStatus":"unaffected","platforms":["Experion LX"],"product":"Experion Server","vendor":"Honeywell","versions":[{"lessThanOrEqual":"520.2 TCU4","status":"affected","version":"520.2","versionType":"semver"},{"lessThanOrEqual":"511.5 TCU4 HF3","status":"affected","version":"511.1","versionType":"semver"},{"lessThanOrEqual":"520.1 TCU4","status":"affected","version":"520.1","versionType":"semver"}]},{"defaultStatus":"unaffected","platforms":["PlantCruise by Experion"],"product":"Experion Server","vendor":"Honeywell","versions":[{"lessThanOrEqual":"520.2 TCU4","status":"affected","version":"520.2","versionType":"semver"},{"lessThanOrEqual":"520.1 TCU4","status":"affected","version":"520.1","versionType":"semver"},{"lessThanOrEqual":"511.5 TCU4 HF3","status":"affected","version":"520.2 TCU4 HFR2","versionType":"semver"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Server receiving a malformed message that causes a disconnect to a hostname may causing a stack overflow resulting in possible remote code execution. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.<br><br> \n\n<br>"}],"value":"Server receiving a malformed message that causes a disconnect to a hostname may causing a stack overflow resulting in possible remote code execution. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.\n\n \n\n"}],"impacts":[{"capecId":"CAPEC-47","descriptions":[{"lang":"en","value":"CAPEC-47"}]}],"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.4,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-130","description":"CWE-130","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"0dc86260-d7e3-4e81-ba06-3508e030ce8d","shortName":"Honeywell","dateUpdated":"2024-04-25T16:55:04.443Z"},"references":[{"url":"https://process.honeywell.com"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2023-5393","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"version":"2.0.3","timestamp":"2024-05-15T18:37:37.313463Z"}}}],"providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-06-04T17:28:36.427Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T07:59:44.301Z"},"title":"CVE Program Container","references":[{"url":"https://process.honeywell.com","tags":["x_transferred"]}]}]}}