{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-5188","assignerOrgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","state":"PUBLISHED","assignerShortName":"CERTVDE","dateReserved":"2023-09-26T05:25:11.663Z","datePublished":"2023-12-05T07:19:08.528Z","dateUpdated":"2024-08-02T07:52:07.789Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"Telecontrol Configurator","vendor":"WAGO","versions":[{"status":"affected","version":"*"}]},{"defaultStatus":"unaffected","product":"WagoAppRTU","vendor":"WAGO","versions":[{"lessThan":"1.4.6.0","status":"affected","version":"0","versionType":"semver"}]}],"credits":[{"lang":"en","type":"reporter","user":"00000000-0000-4000-9000-000000000000","value":"Sofia Pisani"}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"The MMS Interpreter of WagoAppRTU in versions below 1.4.6.0 which is used by the WAGO Telecontrol Configurator is vulnerable to malformed packets. An remote unauthenticated attacker could send specifically crafted packets that lead to a denial-of-service condition until restart of the affected device."}],"value":"The MMS Interpreter of WagoAppRTU in versions below 1.4.6.0 which is used by the WAGO Telecontrol Configurator is vulnerable to malformed packets. An remote unauthenticated attacker could send specifically crafted packets that lead to a denial-of-service condition until restart of the affected device."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-20","description":"CWE-20 Improper Input Validation","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","shortName":"CERTVDE","dateUpdated":"2023-12-14T14:09:31.201Z"},"references":[{"url":"https://cert.vde.com/en/advisories/VDE-2023-044/"}],"source":{"advisory":"VDE-2023-044","defect":["CERT@VDE#64591"],"discovery":"EXTERNAL"},"title":"WAGO Improper Input Validation in IEC61850 Server / Telecontrol","x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T07:52:07.789Z"},"title":"CVE Program Container","references":[{"url":"https://cert.vde.com/en/advisories/VDE-2023-044/","tags":["x_transferred"]}]}]}}