{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-5059","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","state":"PUBLISHED","assignerShortName":"icscert","dateReserved":"2023-09-18T22:39:02.791Z","datePublished":"2023-10-19T17:27:16.081Z","dateUpdated":"2025-01-16T21:29:06.591Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"Sante FFT Imaging","vendor":"Santesoft","versions":[{"lessThanOrEqual":"v1.4.0","status":"affected","version":"0","versionType":"custom"}]}],"credits":[{"lang":"en","type":"finder","user":"00000000-0000-4000-9000-000000000000","value":"Michael Heinzl reported these vulnerabilities to CISA."}],"datePublic":"2023-10-12T17:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\n<span style=\"background-color: rgb(255, 255, 255);\">\n\n<span style=\"background-color: rgb(255, 255, 255);\">\n\n<span style=\"background-color: rgb(255, 255, 255);\">Santesoft Sante FFT Imaging lacks proper validation of user-supplied data when parsing DICOM files. This could lead to an out-of-bounds read. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process.</span></span></span>"}],"value":"\n\n\n\n\nSantesoft Sante FFT Imaging lacks proper validation of user-supplied data when parsing DICOM files. This could lead to an out-of-bounds read. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-125","description":"CWE-125 Out-of-bounds Read","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert","dateUpdated":"2023-10-19T17:27:16.081Z"},"references":[{"url":"https://www.cisa.gov/news-events/ics-medical-advisories/icsma-23-285-02"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\n\n\n<span style=\"background-color: rgb(255, 255, 255);\">Santesoft has released an updated version of their product and recommends users update to Sante FFT Imaging to </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://santesoft.com/win/sante-fft-imaging/download.html\">v1.4.1</a><span style=\"background-color: rgb(255, 255, 255);\">.</span>\n\n\n\n<br>"}],"value":"\n\n\nSantesoft has released an updated version of their product and recommends users update to Sante FFT Imaging to  v1.4.1 https://santesoft.com/win/sante-fft-imaging/download.html .\n\n\n\n\n"}],"source":{"advisory":"ICSMA-23-285-02","discovery":"EXTERNAL"},"title":"Santesoft Sante FFT Imaging Out-of-bounds Read","x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T07:44:53.940Z"},"title":"CVE Program Container","references":[{"url":"https://www.cisa.gov/news-events/ics-medical-advisories/icsma-23-285-02","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-01-16T21:20:18.747921Z","id":"CVE-2023-5059","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-01-16T21:29:06.591Z"}}]}}