{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"state":"PUBLISHED","cveId":"CVE-2023-49515","assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","dateUpdated":"2024-08-02T22:01:24.442Z","dateReserved":"2023-11-27T00:00:00.000Z","datePublished":"2024-01-17T00:00:00.000Z"},"containers":{"cna":{"providerMetadata":{"orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre","dateUpdated":"2024-01-17T01:53:28.775Z"},"descriptions":[{"lang":"en","value":"Insecure Permissiosn vulnerability in TP Link TC70 and C200 WIFI Camera v.3 firmware v.1.3.4 and fixed in v.1.3.11 allows a physically proximate attacker to obtain sensitive information via a connection to the UART pin components."}],"affected":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}],"references":[{"url":"https://github.com/VineethKumarM/TAPO-TC70-Unauthorized-root-access-using-UART/tree/master"},{"url":"https://github.com/VineethKumarM/TAPO-TC70-Unauthorized-root-access-using-UART"}],"problemTypes":[{"descriptions":[{"type":"text","lang":"en","description":"n/a"}]}]},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"cvssV3_1":{"scope":"UNCHANGED","version":"3.1","baseScore":4.6,"attackVector":"PHYSICAL","baseSeverity":"MEDIUM","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","integrityImpact":"NONE","userInteraction":"NONE","attackComplexity":"LOW","availabilityImpact":"NONE","privilegesRequired":"NONE","confidentialityImpact":"HIGH"}},{"other":{"type":"ssvc","content":{"id":"CVE-2023-49515","role":"CISA Coordinator","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"partial"}],"version":"2.0.3","timestamp":"2024-04-22T17:03:22.219740Z"}}}],"affected":[{"cpes":["cpe:2.3:o:tp-link:tapo_tc70_firmware:1.3.4:*:*:*:*:*:*:*"],"vendor":"tp-link","product":"tapo_tc70_firmware","versions":[{"status":"affected","version":"1.3.4"}],"defaultStatus":"unknown"},{"cpes":["cpe:2.3:a:tp-link:tapo_c200_v3_firmware:-:*:*:*:*:*:*:*"],"vendor":"tp-link","product":"tapo_c200_v3_firmware","versions":[{"status":"affected","version":"1.3.4"}],"defaultStatus":"unknown"}],"problemTypes":[{"descriptions":[{"lang":"en","type":"CWE","cweId":"CWE-922","description":"CWE-922 Insecure Storage of Sensitive Information"}]}],"providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-06-04T17:27:49.172Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T22:01:24.442Z"},"title":"CVE Program Container","references":[{"url":"https://github.com/VineethKumarM/TAPO-TC70-Unauthorized-root-access-using-UART/tree/master","tags":["x_transferred"]},{"url":"https://github.com/VineethKumarM/TAPO-TC70-Unauthorized-root-access-using-UART","tags":["x_transferred"]}]}]}}