{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-45844","assignerOrgId":"c95f66b2-7e7c-41c5-8f09-6f86ec68659c","state":"PUBLISHED","assignerShortName":"bosch","dateReserved":"2023-10-18T09:35:22.486Z","datePublished":"2023-10-25T13:07:15.053Z","dateUpdated":"2024-09-10T20:24:25.472Z"},"containers":{"cna":{"providerMetadata":{"orgId":"c95f66b2-7e7c-41c5-8f09-6f86ec68659c","shortName":"bosch","dateUpdated":"2023-10-25T13:07:15.053Z"},"descriptions":[{"lang":"en","value":"The vulnerability allows a low privileged user that have access to the device when locked in Kiosk mode to install an arbitrary Android application and leverage it to have access to critical device settings such as the device power management or eventually the device secure settings (ADB debug)."}],"affected":[{"vendor":"Rexroth","product":"ctrlX HMI Web Panel - WR21 (WR2107)","versions":[{"version":"all","status":"affected"}]},{"vendor":"Rexroth","product":"ctrlX HMI Web Panel - WR21 (WR2110)","versions":[{"version":"all","status":"affected"}]},{"vendor":"Rexroth","product":"ctrlX HMI Web Panel - WR21 (WR2115)","versions":[{"version":"all","status":"affected"}]}],"problemTypes":[{"descriptions":[{"lang":"en-US","description":"CWE-284 Improper Access Control","cweId":"CWE-284"}]}],"references":[{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html","name":"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html","tags":["vendor-advisory"]}],"metrics":[{"cvssV3_0":{"version":"3.0","vectorString":"CVSS:3.0/AV:P/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H","attackVector":"PHYSICAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.3,"baseSeverity":"HIGH"}}]},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T20:29:32.423Z"},"title":"CVE Program Container","references":[{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html","name":"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html","tags":["vendor-advisory","x_transferred"]}]},{"problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-284","lang":"en","description":"CWE-284 Improper Access Control"}]}],"affected":[{"vendor":"rexroth","product":"ctrlx_hmi_web_panel_wr21\\/wr2107\\/","cpes":["cpe:2.3:o:rexroth:ctrlx_hmi_web_panel_wr21\\/wr2107\\/:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThanOrEqual":"*","versionType":"custom"}]},{"vendor":"rexroth","product":"ctrlx_hmi_web_panel_wr21\\/wr2110\\/","cpes":["cpe:2.3:o:rexroth:ctrlx_hmi_web_panel_wr21\\/wr2110\\/:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThanOrEqual":"*","versionType":"custom"}]},{"vendor":"rexroth","product":"ctrlx_hmi_web_panel_wr21\\/wr2115\\/","cpes":["cpe:2.3:o:rexroth:ctrlx_hmi_web_panel_wr21\\/wr2115\\/:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThanOrEqual":"*","versionType":"custom"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-09-10T20:05:44.966105Z","id":"CVE-2023-45844","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-09-10T20:24:25.472Z"}}]}}