{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-45320","assignerOrgId":"6dda929c-bb53-4a77-a76d-48e79601a1ce","state":"PUBLISHED","assignerShortName":"intel","dateReserved":"2023-11-03T03:00:20.874Z","datePublished":"2024-05-16T20:47:27.184Z","dateUpdated":"2024-08-02T20:21:15.392Z"},"containers":{"cna":{"providerMetadata":{"orgId":"6dda929c-bb53-4a77-a76d-48e79601a1ce","shortName":"intel","dateUpdated":"2024-05-16T20:47:27.184Z"},"problemTypes":[{"descriptions":[{"lang":"en","description":"escalation of privilege"},{"lang":"en","description":"Uncontrolled search path element","cweId":"CWE-427","type":"CWE"}]}],"affected":[{"vendor":"n/a","product":"Intel(R) VTune(TM) Profiler software","versions":[{"version":"before version 2024.0","status":"affected"}],"defaultStatus":"unaffected"}],"descriptions":[{"lang":"en","value":"Uncontrolled search path element in some Intel(R) VTune(TM) Profiler software before version 2024.0 may allow an authenticated user to potentially enable escalation of privilege via local access."}],"references":[{"name":"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01034.html","url":"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01034.html"}],"metrics":[{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV3_1":{"version":"3.1","baseScore":6.7,"baseSeverity":"MEDIUM","vectorString":"CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"HIGH","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}}]},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2023-45320","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"version":"2.0.3","timestamp":"2024-05-24T15:56:30.411157Z"}}}],"affected":[{"cpes":["cpe:2.3:a:intel:vtune_profiler:*:*:*:*:*:*:*:*"],"vendor":"intel","product":"vtune_profiler","versions":[{"status":"affected","version":"0","lessThan":"2024.0","versionType":"custom"}],"defaultStatus":"unknown"}],"problemTypes":[{"descriptions":[{"lang":"en","type":"CWE","cweId":"CWE-269","description":"CWE-269 Improper Privilege Management"}]},{"descriptions":[{"lang":"en","type":"CWE","cweId":"CWE-427","description":"CWE-427 Uncontrolled Search Path Element"}]}],"providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-06-04T17:19:55.269Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T20:21:15.392Z"},"title":"CVE Program Container","references":[{"name":"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01034.html","url":"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01034.html","tags":["x_transferred"]}]}]}}