{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-44317","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","state":"PUBLISHED","assignerShortName":"siemens","dateReserved":"2023-09-28T16:18:45.647Z","datePublished":"2023-11-14T11:03:48.999Z","dateUpdated":"2025-01-14T10:28:24.686Z"},"containers":{"cna":{"providerMetadata":{"orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens","dateUpdated":"2025-01-14T10:28:24.686Z"},"descriptions":[{"lang":"en","value":"A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V7.2.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V7.2.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V7.2.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V7.2.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V7.2.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V7.2.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V7.2.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V7.2.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V7.2.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V7.2.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V7.2.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V7.2.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V7.2.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V7.2.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V7.2.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V7.2.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V7.2.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V7.2.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V7.2.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V7.2.2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected products do not properly validate the content of uploaded X509 certificates which could allow an attacker with administrative privileges to execute arbitrary code on the device."}],"affected":[{"vendor":"Siemens","product":"RUGGEDCOM RM1224 LTE(4G) EU","versions":[{"status":"affected","version":"0","lessThan":"V7.2.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RM1224 LTE(4G) NAM","versions":[{"status":"affected","version":"0","lessThan":"V7.2.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M804PB","versions":[{"status":"affected","version":"0","lessThan":"V7.2.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M812-1 ADSL-Router","versions":[{"status":"affected","version":"0","lessThan":"V7.2.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M812-1 ADSL-Router","versions":[{"status":"affected","version":"0","lessThan":"V7.2.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M816-1 ADSL-Router","versions":[{"status":"affected","version":"0","lessThan":"V7.2.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M816-1 ADSL-Router","versions":[{"status":"affected","version":"0","lessThan":"V7.2.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M826-2 SHDSL-Router","versions":[{"status":"affected","version":"0","lessThan":"V7.2.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M874-2","versions":[{"status":"affected","version":"0","lessThan":"V7.2.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M874-3","versions":[{"status":"affected","version":"0","lessThan":"V7.2.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M876-3","versions":[{"status":"affected","version":"0","lessThan":"V7.2.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M876-3 (ROK)","versions":[{"status":"affected","version":"0","lessThan":"V7.2.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M876-4","versions":[{"status":"affected","version":"0","lessThan":"V7.2.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M876-4 (EU)","versions":[{"status":"affected","version":"0","lessThan":"V7.2.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M876-4 (NAM)","versions":[{"status":"affected","version":"0","lessThan":"V7.2.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE MUM853-1 (EU)","versions":[{"status":"affected","version":"0","lessThan":"V7.2.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE MUM856-1 (EU)","versions":[{"status":"affected","version":"0","lessThan":"V7.2.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE MUM856-1 (RoW)","versions":[{"status":"affected","version":"0","lessThan":"V7.2.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE S615 EEC LAN-Router","versions":[{"status":"affected","version":"0","lessThan":"V7.2.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE S615 LAN-Router","versions":[{"status":"affected","version":"0","lessThan":"V7.2.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WAB762-1","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WAM763-1","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WAM763-1 (ME)","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WAM763-1 (US)","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WAM766-1","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WAM766-1 (ME)","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WAM766-1 (US)","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WAM766-1 EEC","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WAM766-1 EEC (ME)","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WAM766-1 EEC (US)","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WUB762-1","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WUB762-1 iFeatures","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WUM763-1","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WUM763-1","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WUM763-1 (US)","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WUM763-1 (US)","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WUM766-1","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WUM766-1 (ME)","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WUM766-1 (USA)","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","baseScore":7.2,"baseSeverity":"HIGH"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseScore":8.6,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-349","description":"CWE-349: Acceptance of Extraneous Untrusted Data With Trusted Data","type":"CWE"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-699386.pdf"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-068047.pdf"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-699386.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-068047.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-602936.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-690517.html"}]},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T19:59:52.114Z"},"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-699386.pdf","tags":["x_transferred"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-068047.pdf","tags":["x_transferred"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-699386.html","tags":["x_transferred"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-068047.html","tags":["x_transferred"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-602936.html","tags":["x_transferred"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-690517.html","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2023-12-09T05:05:39.591638Z","id":"CVE-2023-44317","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-01-08T16:17:22.554Z"}}]}}