{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-4401","assignerOrgId":"c550e75a-17ff-4988-97f0-544cde3820fe","state":"PUBLISHED","assignerShortName":"dell","dateReserved":"2023-08-17T10:11:34.829Z","datePublished":"2023-10-05T17:12:17.987Z","dateUpdated":"2024-09-19T18:52:12.000Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"Dell SmartFabric Storage Software","vendor":"Dell","versions":[{"status":"affected","version":" v1.4.0 and prior"}]}],"datePublic":"2023-09-28T06:30:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\n<span style=\"background-color: rgb(255, 255, 255);\">Dell SmartFabric Storage Software v1.4 (and earlier) contains an OS Command Injection Vulnerability in the CLI use of the ‘more’ command. A local or remote authenticated attacker could potentially exploit this vulnerability, leading to the ability to gain root-level access.</span>\n\n"}],"value":"\nDell SmartFabric Storage Software v1.4 (and earlier) contains an OS Command Injection Vulnerability in the CLI use of the ‘more’ command. A local or remote authenticated attacker could potentially exploit this vulnerability, leading to the ability to gain root-level access.\n\n"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-77","description":"CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"c550e75a-17ff-4988-97f0-544cde3820fe","shortName":"dell","dateUpdated":"2023-10-05T17:12:17.987Z"},"references":[{"tags":["vendor-advisory"],"url":"https://www.dell.com/support/kbdoc/en-us/000218107/dsa-2023-347-dell-smartfabric-storage-software-security-update-for-multiple-vulnerabilities"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T07:24:04.623Z"},"title":"CVE Program Container","references":[{"tags":["vendor-advisory","x_transferred"],"url":"https://www.dell.com/support/kbdoc/en-us/000218107/dsa-2023-347-dell-smartfabric-storage-software-security-update-for-multiple-vulnerabilities"}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-09-19T18:51:52.414230Z","id":"CVE-2023-4401","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-09-19T18:52:12.000Z"}}]}}