{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-43488","assignerOrgId":"c95f66b2-7e7c-41c5-8f09-6f86ec68659c","state":"PUBLISHED","assignerShortName":"bosch","dateReserved":"2023-10-18T09:35:22.492Z","datePublished":"2023-10-25T13:27:09.366Z","dateUpdated":"2024-09-17T14:06:24.603Z"},"containers":{"cna":{"providerMetadata":{"orgId":"c95f66b2-7e7c-41c5-8f09-6f86ec68659c","shortName":"bosch","dateUpdated":"2023-10-25T13:27:09.366Z"},"descriptions":[{"lang":"en","value":"The vulnerability allows a low privileged (untrusted) application to\r\nmodify a critical system property that should be denied, in order to enable the ADB (Android Debug Bridge) protocol to be exposed on the network, exploiting it to gain a privileged shell on the device without requiring the physical access through USB."}],"affected":[{"vendor":"Rexroth","product":"ctrlX HMI Web Panel - WR21 (WR2107)","versions":[{"version":"all","status":"affected"}]},{"vendor":"Rexroth","product":"ctrlX HMI Web Panel - WR21 (WR2110)","versions":[{"version":"all","status":"affected"}]},{"vendor":"Rexroth","product":"ctrlX HMI Web Panel - WR21 (WR2115)","versions":[{"version":"all","status":"affected"}]}],"problemTypes":[{"descriptions":[{"lang":"en-US","description":"CWE-862 Missing Authorization","cweId":"CWE-862"}]}],"references":[{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html","name":"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html","tags":["vendor-advisory"]}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:H/A:L","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"HIGH","availabilityImpact":"LOW","baseScore":7.9,"baseSeverity":"HIGH"}}]},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T19:44:42.209Z"},"title":"CVE Program Container","references":[{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html","name":"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html","tags":["vendor-advisory","x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-09-11T13:32:31.772490Z","id":"CVE-2023-43488","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-09-17T14:06:24.603Z"}}]}}