{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-41033","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","state":"PUBLISHED","assignerShortName":"siemens","dateReserved":"2023-08-22T15:41:08.130Z","datePublished":"2023-09-12T09:32:34.938Z","dateUpdated":"2025-02-27T20:55:04.635Z"},"containers":{"cna":{"providerMetadata":{"orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens","dateUpdated":"2023-11-14T11:03:43.928Z"},"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.260), Parasolid V35.1 (All versions < V35.1.246), Parasolid V36.0 (All versions < V36.0.156), Simcenter Femap V2301 (All versions < V2301.0003), Simcenter Femap V2306 (All versions < V2306.0001). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21266)"}],"affected":[{"vendor":"Siemens","product":"Parasolid V35.0","versions":[{"version":"All versions < V35.0.260","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Parasolid V35.1","versions":[{"version":"All versions < V35.1.246","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Parasolid V36.0","versions":[{"version":"All versions < V36.0.156","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Simcenter Femap V2301","versions":[{"version":"All versions < V2301.0003","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Simcenter Femap V2306","versions":[{"version":"All versions < V2306.0001","status":"affected"}],"defaultStatus":"unknown"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","baseScore":7.8,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-787","description":"CWE-787: Out-of-bounds Write","type":"CWE"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-190839.pdf"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-887122.pdf"}]},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T18:46:11.479Z"},"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-190839.pdf","tags":["x_transferred"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-887122.pdf","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-02-26T21:51:44.895132Z","id":"CVE-2023-41033","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-02-27T20:55:04.635Z"}}]}}