{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-38073","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","state":"PUBLISHED","assignerShortName":"siemens","dateReserved":"2023-07-12T13:18:53.822Z","datePublished":"2023-09-12T09:32:16.855Z","dateUpdated":"2024-08-02T17:30:14.105Z"},"containers":{"cna":{"providerMetadata":{"orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens","dateUpdated":"2023-11-14T11:03:24.893Z"},"descriptions":[{"lang":"en","value":"A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains a type confusion vulnerability while parsing WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20826)"}],"affected":[{"vendor":"Siemens","product":"JT2Go","versions":[{"version":"All versions < V14.3.0.1","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Teamcenter Visualization V13.3","versions":[{"version":"All versions < V13.3.0.12","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Teamcenter Visualization V14.0","versions":[{"version":"All versions","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Teamcenter Visualization V14.1","versions":[{"version":"All versions < V14.1.0.11","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Teamcenter Visualization V14.2","versions":[{"version":"All versions < V14.2.0.6","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Teamcenter Visualization V14.3","versions":[{"version":"All versions < V14.3.0.1","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2201","versions":[{"version":"All versions < V2201.0010","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2302","versions":[{"version":"All versions < V2302.0004","status":"affected"}],"defaultStatus":"unknown"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","baseScore":7.8,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-843","description":"CWE-843: Access of Resource Using Incompatible Type ('Type Confusion')","type":"CWE"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"}]},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T17:30:14.105Z"},"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf","tags":["x_transferred"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf","tags":["x_transferred"]}]}]}}