{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-37216","assignerOrgId":"a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f","state":"PUBLISHED","assignerShortName":"INCD","dateReserved":"2023-06-28T20:35:37.791Z","datePublished":"2023-07-30T09:03:13.073Z","dateUpdated":"2024-10-21T18:02:54.101Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"SensMini M4","vendor":"AnaSystem","versions":[{"status":"affected","version":"All versions"}]}],"credits":[{"lang":"en","type":"finder","user":"00000000-0000-4000-9000-000000000000","value":"MetaData"}],"datePublic":"2023-07-30T08:40:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"  \n\n<span style=\"background-color: rgb(255, 255, 255);\"> AnaSystem SensMini M4 – Using the configuration tool, an authenticated user can cause Denial of Service for the device</span>\n\n"}],"value":"  \n\n AnaSystem SensMini M4 – Using the configuration tool, an authenticated user can cause Denial of Service for the device\n\n"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"providerMetadata":{"orgId":"a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f","shortName":"INCD","dateUpdated":"2023-07-30T09:03:13.073Z"},"references":[{"url":"https://www.gov.il/en/Departments/faq/cve_advisories"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\n<span style=\"background-color: rgb(255, 255, 255);\">\n\n<span style=\"background-color: rgb(255, 255, 255);\">The product is EOL. Upgrade to another product. As a workaround, limit access to the device and configuration tool.</span>\n\n</span>\n\n<br>"}],"value":"\n\n\nThe product is EOL. Upgrade to another product. As a workaround, limit access to the device and configuration tool.\n\n\n\n\n"}],"source":{"advisory":"ILVN-2023-0118","discovery":"UNKNOWN"},"title":" AnaSystem SensMini M4 – an authenticated user can cause Denial of Service","x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T17:09:34.177Z"},"title":"CVE Program Container","references":[{"url":"https://www.gov.il/en/Departments/faq/cve_advisories","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-10-21T18:02:39.375690Z","id":"CVE-2023-37216","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-10-21T18:02:54.101Z"}}]}}