{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-37200","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","state":"PUBLISHED","assignerShortName":"schneider","dateReserved":"2023-06-28T14:14:13.863Z","datePublished":"2023-07-12T07:11:30.005Z","dateUpdated":"2024-11-07T14:07:40.931Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"EcoStruxure OPC UA Server Expert","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Versions prior to SV2.01 SP2"}]}],"datePublic":"2023-07-11T07:10:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\nA CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that\ncould cause loss of confidentiality when replacing a project file on the local filesystem and after\nmanual restart of the server. \n\n\n"}],"value":"\nA CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that\ncould cause loss of confidentiality when replacing a project file on the local filesystem and after\nmanual restart of the server. \n\n\n"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"NONE","baseScore":5.5,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-611","description":"CWE-611 Improper Restriction of XML External Entity Reference","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider","dateUpdated":"2023-07-12T07:11:30.005Z"},"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-02.pdf"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T17:09:32.655Z"},"title":"CVE Program Container","references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-02.pdf","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-11-07T14:06:52.880283Z","id":"CVE-2023-37200","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-11-07T14:07:40.931Z"}}]}}