{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-37199","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","state":"PUBLISHED","assignerShortName":"schneider","dateReserved":"2023-06-28T14:14:13.863Z","datePublished":"2023-07-12T07:04:08.510Z","dateUpdated":"2024-11-07T14:44:46.940Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"StruxureWare Data Center Expert ","vendor":"Schneider Electric","versions":[{"status":"affected","version":"v7.9.3 and earlier"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\nA CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that\ncould cause remote code execution when an admin user on DCE tampers with backups which\nare then manually restored. \n\n\n"}],"value":"\nA CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that\ncould cause remote code execution when an admin user on DCE tampers with backups which\nare then manually restored. \n\n\n"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":6.8,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-94","description":"CWE-94 Improper Control of Generation of Code ('Code Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider","dateUpdated":"2023-07-12T07:04:08.510Z"},"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-01.pdf"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T17:09:33.130Z"},"title":"CVE Program Container","references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-01.pdf","tags":["x_transferred"]}]},{"affected":[{"vendor":"schneider-electric","product":"struxureware_data_center_expert","cpes":["cpe:2.3:a:schneider-electric:struxureware_data_center_expert:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThanOrEqual":"7.9.3","versionType":"custom"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-11-07T14:42:11.667073Z","id":"CVE-2023-37199","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-11-07T14:44:46.940Z"}}]}}