{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2023-35696","assignerOrgId":"a6863dd2-93fc-443d-bef1-79f0b5020988","state":"PUBLISHED","assignerShortName":"SICK AG","dateReserved":"2023-06-15T11:32:19.767Z","datePublished":"2023-07-10T09:32:57.842Z","dateUpdated":"2026-06-01T12:12:37.020Z"},"containers":{"cna":{"providerMetadata":{"orgId":"a6863dd2-93fc-443d-bef1-79f0b5020988","shortName":"SICK AG","dateUpdated":"2026-06-01T12:12:37.020Z"},"problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-668","description":"CWE-668 Exposure of Resource to Wrong Sphere","type":"CWE"}]}],"affected":[{"vendor":"SICK AG","product":"ICR890-4","versions":[{"status":"affected","version":"0","lessThan":"2.5.0","versionType":"*"}],"defaultStatus":"affected"}],"descriptions":[{"lang":"en","value":"Unauthenticated endpoints in the SICK ICR890-4 could allow an unauthenticated\nremote attacker to retrieve sensitive information about the device via HTTP requests.","supportingMedia":[{"type":"text/html","base64":false,"value":"Unauthenticated endpoints in the SICK ICR890-4 could allow an unauthenticated\nremote attacker to retrieve sensitive information about the device via HTTP requests."}]}],"references":[{"url":"https://sick.com/psirt","tags":["issue-tracking"]},{"url":"https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.pdf","tags":["vendor-advisory"]},{"url":"https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.json","tags":["x_csaf"]}],"metrics":[{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV3_1":{"version":"3.1","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","baseSeverity":"HIGH","baseScore":7.5,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"}}],"solutions":[{"lang":"en","value":"The recommended solution is to update the firmware to a version >= V2.5.0 as soon as\npossible.","supportingMedia":[{"type":"text/html","base64":false,"value":"The recommended solution is to update the firmware to a version &gt;= V2.5.0 as soon as\npossible.\n\n<br>"}]}],"source":{"discovery":"INTERNAL"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T16:30:44.643Z"},"title":"CVE Program Container","references":[{"tags":["issue-tracking","x_transferred"],"url":"https://sick.com/psirt"},{"tags":["vendor-advisory","x_transferred"],"url":"https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.pdf"},{"tags":["x_csaf","x_transferred"],"url":"https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.json"}]},{"affected":[{"vendor":"sick_ag","product":"icr890-4","cpes":["cpe:2.3:a:sick_ag:icr890-4:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"2.5.0","versionType":"custom"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-11-12T14:38:05.414683Z","id":"CVE-2023-35696","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-11-12T14:38:32.412Z"}}]}}