{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-33217","assignerOrgId":"a87f365f-9d39-4848-9b3a-58c7cae69cab","state":"PUBLISHED","assignerShortName":"IDEMIA","dateReserved":"2023-05-18T14:32:49.222Z","datePublished":"2023-12-15T10:45:30.637Z","dateUpdated":"2024-08-02T15:39:35.734Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"SIGMA Lite & Lite +","vendor":"IDEMIA","versions":[{"lessThan":"4.15.5","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"SIGMA Wide","vendor":"IDEMIA","versions":[{"lessThan":"4.15.5","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"SIGMA Extreme","vendor":"IDEMIA","versions":[{"lessThan":"4.15.5","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"MorphoWave Compact/XP","vendor":"IDEMIA","versions":[{"lessThan":"2.12.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VisionPass","vendor":"IDEMIA","versions":[{"lessThan":"2.12.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"MorphoWave SP","vendor":"IDEMIA","versions":[{"lessThan":"1.2.7","status":"affected","version":"0","versionType":"custom"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\nBy abusing a design flaw in the firmware upgrade mechanism of the impacted terminal it's possible to cause a permanent \ndenial of service for the terminal. the only way to recover the terminal is by sending back the terminal to the manufacturer"}],"value":"\nBy abusing a design flaw in the firmware upgrade mechanism of the impacted terminal it's possible to cause a permanent \ndenial of service for the terminal. the only way to recover the terminal is by sending back the terminal to the manufacturer"}],"impacts":[{"capecId":"CAPEC-153","descriptions":[{"lang":"en","value":"CAPEC-153 Input Data Manipulation"}]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":4.9,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"if you have kept the default Enforced Security mode or enabled the mTLS to identify the origin of the  command issued to the termina"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-20","description":"CWE-20 Improper Input Validation","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"a87f365f-9d39-4848-9b3a-58c7cae69cab","shortName":"IDEMIA","dateUpdated":"2023-12-15T10:45:30.637Z"},"references":[{"url":"https://www.idemia.com/wp-content/uploads/2023/11/Security-Advisory-SA-2023-05-2.pdf"}],"source":{"discovery":"UNKNOWN"},"title":"Missing integrity check on upgrade package","x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T15:39:35.734Z"},"title":"CVE Program Container","references":[{"url":"https://www.idemia.com/wp-content/uploads/2023/11/Security-Advisory-SA-2023-05-2.pdf","tags":["x_transferred"]}]}]}}