{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-30765","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","state":"PUBLISHED","assignerShortName":"icscert","dateReserved":"2023-06-06T14:32:07.388Z","datePublished":"2023-07-10T19:04:41.114Z","dateUpdated":"2025-01-27T16:19:08.718Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"Infrasuite Device Master","vendor":"Delta Electronics","versions":[{"lessThan":"v1.0.7","status":"affected","version":"0","versionType":"custom"}]}],"credits":[{"lang":"en","type":"finder","user":"00000000-0000-4000-9000-000000000000","value":"​Piotr Bazydlo of Trend Micro’s Zero Day Initiative reported these vulnerabilities to CISA."}],"datePublic":"2023-06-29T17:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<span style=\"background-color: rgb(255, 255, 255);\">\n\n<span style=\"background-color: rgb(255, 255, 255);\">​Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contain improper access controls that could allow an attacker to alter privilege management configurations, resulting in privilege escalation.</span>\n\n</span>"}],"value":"​Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contain improper access controls that could allow an attacker to alter privilege management configurations, resulting in privilege escalation."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-269","description":"CWE-269 Improper Privilege Management","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert","dateUpdated":"2025-01-27T16:19:08.718Z"},"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-180-01"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>​Delta Electronics has provided a fix to these vulnerabilities. Users are encouraged to update to the latest version.</p><ul><li>​Delta Electronics InfraSuite Device Master: Update to <a target=\"_blank\" rel=\"nofollow\" href=\"https://datacenter-softwarecenter.deltaww.com/Download/UPS/Software/InfraSuite_Device_Master_1.0.7(x64).exe\">v1.0.7</a>.</li></ul>"}],"value":"​Delta Electronics has provided a fix to these vulnerabilities. Users are encouraged to update to the latest version.\n\n  *  ​Delta Electronics InfraSuite Device Master: Update to  v1.0.7 https://datacenter-softwarecenter.deltaww.com/Download/UPS/Software/InfraSuite_Device_Master_1.0.7(x64).exe ."}],"source":{"advisory":"ICSA-23-180-01","discovery":"EXTERNAL"},"title":"​Delta Electronics InfraSuite Device Master Improper Access Control","x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T14:37:15.316Z"},"title":"CVE Program Container","references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-180-01","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-11-08T16:34:08.154196Z","id":"CVE-2023-30765","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-11-08T16:34:17.587Z"}}]}}