{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-2993","assignerOrgId":"da227ddf-6e25-4b41-b023-0f976dcaca4b","state":"PUBLISHED","assignerShortName":"lenovo","dateReserved":"2023-05-30T16:27:50.393Z","datePublished":"2023-06-26T19:44:50.040Z","dateUpdated":"2024-11-06T21:47:48.605Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"System Management Module (SMM) ","vendor":"Lenovo","versions":[{"status":"affected","version":"various"}]},{"defaultStatus":"unaffected","product":"Fan Power Controller (FPC)","vendor":"Lenovo","versions":[{"status":"affected","version":"various"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"A valid, authenticated user with limited privileges may be able to use specifically crafted web management server API calls to execute a limited number of commands on SMM v1, SMM v2, and FPC that the user does not normally have sufficient privileges to execute."}],"value":"A valid, authenticated user with limited privileges may be able to use specifically crafted web management server API calls to execute a limited number of commands on SMM v1, SMM v2, and FPC that the user does not normally have sufficient privileges to execute."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":5.4,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-281","description":"CWE-281 Improper Preservation of Permissions","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"da227ddf-6e25-4b41-b023-0f976dcaca4b","shortName":"lenovo","dateUpdated":"2023-06-26T19:44:50.040Z"},"references":[{"url":"https://support.lenovo.com/us/en/product_security/LEN-127357"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Upgrade to the firmware version (or newer) indicated for your model in the advisory: <a target=\"_blank\" rel=\"nofollow\" href=\"https://support.lenovo.com/us/en/product_security/LEN-127357\">https://support.lenovo.com/us/en/product_security/LEN-127357</a>"}],"value":"Upgrade to the firmware version (or newer) indicated for your model in the advisory:  https://support.lenovo.com/us/en/product_security/LEN-127357 https://support.lenovo.com/us/en/product_security/LEN-127357 "}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T06:41:04.129Z"},"title":"CVE Program Container","references":[{"url":"https://support.lenovo.com/us/en/product_security/LEN-127357","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-11-06T21:46:22.855451Z","id":"CVE-2023-2993","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-11-06T21:47:48.605Z"}}]}}