{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-29412","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","state":"PUBLISHED","assignerShortName":"schneider","dateReserved":"2023-04-05T20:35:41.367Z","datePublished":"2023-04-18T20:50:08.288Z","dateUpdated":"2025-02-05T21:00:38.906Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)","vendor":"Schneider Electric","versions":[{"lessThanOrEqual":"prior","status":"affected","version":"V2.5-GA-01-22320","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)","vendor":"Schneider Electric","versions":[{"lessThanOrEqual":"prior","status":"affected","version":"V2.5-GS-01-22320","versionType":"custom"}]}],"datePublic":"2023-04-11T07:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\nCWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command\nInjection') vulnerability exists that could cause remote code execution when manipulating\ninternal methods through Java RMI interface.\n\n"}],"value":"CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command\nInjection') vulnerability exists that could cause remote code execution when manipulating\ninternal methods through Java RMI interface."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","description":"CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider","dateUpdated":"2024-06-12T12:20:18.929Z"},"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-04.pdf"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T14:07:46.159Z"},"title":"CVE Program Container","references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-04.pdf","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-02-05T21:00:28.496674Z","id":"CVE-2023-29412","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-02-05T21:00:38.906Z"}}]}}