{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-29158","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","state":"PUBLISHED","assignerShortName":"icscert","dateReserved":"2023-05-25T16:04:56.578Z","datePublished":"2023-06-19T20:11:05.873Z","dateUpdated":"2024-12-09T20:49:14.599Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"PowerSYSTEM Center","vendor":"SUBNET Solutions Inc.","versions":[{"lessThanOrEqual":"2020 U10","status":"affected","version":"0","versionType":"custom"}]}],"credits":[{"lang":"en","type":"finder","user":"00000000-0000-4000-9000-000000000000","value":"SUBNET Solutions reported these vulnerabilities to CISA."}],"datePublic":"2023-06-15T20:07:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\n<p>\n\n<span style=\"background-color: rgb(255, 255, 255);\">SUBNET PowerSYSTEM Center versions 2020 U10 and prior are vulnerable to replay attacks which may result in a denial-of-service condition or a loss of data integrity.</span>\n\n</p><br>\n\n"}],"value":"\n\n\nSUBNET PowerSYSTEM Center versions 2020 U10 and prior are vulnerable to replay attacks which may result in a denial-of-service condition or a loss of data integrity.\n\n\n\n\n\n\n"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"HIGH","baseScore":6.1,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-294","description":"CWE-294 Authentication Bypass by Capture-replay","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert","dateUpdated":"2023-06-19T20:11:05.873Z"},"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-01"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\n<p>SUBNET Solutions has fixed these issues by enabling a file integrity check on uploaded images and anti-forgery tokens to prevent replay attacks. The fix was introduced in PowerSYSTEM Center update 12 as well as Update 8+Hotfix (both identified by release number 5.12.2305.10101, which can be located in Settings / Overview / Version).</p><p><br></p>"}],"value":"\nSUBNET Solutions has fixed these issues by enabling a file integrity check on uploaded images and anti-forgery tokens to prevent replay attacks. The fix was introduced in PowerSYSTEM Center update 12 as well as Update 8+Hotfix (both identified by release number 5.12.2305.10101, which can be located in Settings / Overview / Version).\n\n\n\n\n"}],"source":{"discovery":"INTERNAL"},"title":"SUBNET PowerSYSTEM Center Authentication Bypass by Capture-replay","workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\n<p>SUBNET Solutions recommends users to follow the following workarounds:</p><ul><li>Users should verify that SVG files do not contain HTML elements or scripts and validate that JPG and PNG files are not SVG files.</li><li>Users should verify network security rules to ensure that outbound connections to the internet are not possible.</li><li>If the above cannot be performed or notifications are not required, disable email notifications for reports from PowerSYSTEM Center.</li><li>Monitor user activity and ensure application control rules only allow preauthorized executables to run.</li><li>Deny users to run other executables on client access servers (PowerSYSTEM Center front end access point).</li></ul><br>\n\n<br>"}],"value":"\nSUBNET Solutions recommends users to follow the following workarounds:\n\n  *  Users should verify that SVG files do not contain HTML elements or scripts and validate that JPG and PNG files are not SVG files.\n  *  Users should verify network security rules to ensure that outbound connections to the internet are not possible.\n  *  If the above cannot be performed or notifications are not required, disable email notifications for reports from PowerSYSTEM Center.\n  *  Monitor user activity and ensure application control rules only allow preauthorized executables to run.\n  *  Deny users to run other executables on client access servers (PowerSYSTEM Center front end access point).\n\n\n\n\n\n\n"}],"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T14:00:15.368Z"},"title":"CVE Program Container","references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-01","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-12-09T20:48:57.979110Z","id":"CVE-2023-29158","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-12-09T20:49:14.599Z"}}]}}