{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-29054","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","state":"PUBLISHED","assignerShortName":"siemens","dateReserved":"2023-03-30T12:04:26.539Z","datePublished":"2023-04-11T09:03:08.813Z","dateUpdated":"2025-02-07T16:49:26.184Z"},"containers":{"cna":{"providerMetadata":{"orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens","dateUpdated":"2023-04-11T09:03:08.813Z"},"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SIPLUS NET SCALANCE X202-2P IRT (All versions < V5.5.2). The SSH server on affected devices is configured to offer weak ciphers by default.\r\n\r\nThis could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data\r\npassed over the connection between legitimate clients and the affected device."}],"affected":[{"vendor":"Siemens","product":"SCALANCE X200-4P IRT","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X201-3P IRT","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X201-3P IRT PRO","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X202-2IRT","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X202-2IRT","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X202-2P IRT","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X202-2P IRT PRO","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X204IRT","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X204IRT","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X204IRT PRO","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XF201-3P IRT","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XF202-2P IRT","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XF204-2BA IRT","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XF204IRT","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS NET SCALANCE X202-2P IRT","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"defaultStatus":"unknown"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H/E:P/RL:U/RC:C","baseScore":6.7,"baseSeverity":"MEDIUM"}}],"problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-326","description":"CWE-326: Inadequate Encryption Strength","type":"CWE"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-479249.pdf"}]},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T14:00:14.631Z"},"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-479249.pdf","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-02-07T16:49:12.465183Z","id":"CVE-2023-29054","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-02-07T16:49:26.184Z"}}]}}