{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-29023","assignerOrgId":"b73dd486-f505-4403-b634-40b078b177f0","state":"PUBLISHED","assignerShortName":"Rockwell","dateReserved":"2023-03-29T20:07:06.686Z","datePublished":"2023-05-11T17:41:54.222Z","dateUpdated":"2024-08-02T14:00:14.750Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"ArmorStart ST","vendor":"Rockwell Automation","versions":[{"status":"affected","version":"All "}]}],"datePublic":"2023-05-11T14:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\n<span style=\"background-color: rgb(255, 255, 255);\">A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user to view and modify sensitive data or make the web page unavailable. User interaction, such as a phishing attack, is required for successful exploitation of this vulnerability.</span>\n\n"}],"value":"\nA cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user to view and modify sensitive data or make the web page unavailable. User interaction, such as a phishing attack, is required for successful exploitation of this vulnerability.\n\n"}],"impacts":[{"capecId":"CAPEC-63","descriptions":[{"lang":"en","value":"CAPEC-63 Cross-Site Scripting (XSS)"}]}],"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-79","description":"CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"b73dd486-f505-4403-b634-40b078b177f0","shortName":"Rockwell","dateUpdated":"2023-10-24T11:45:38.747Z"},"references":[{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139438"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Customers should disable the webserver during normal use. The webserver is disabled by default and should only be enabled to modify configurations. After modifying configurations, the web server should be disabled."}],"value":"Customers should disable the webserver during normal use. The webserver is disabled by default and should only be enabled to modify configurations. After modifying configurations, the web server should be disabled."}],"source":{"discovery":"UNKNOWN"},"title":"Rockwell Automation ArmorStart ST Vulnerable to Cross-Site Scripting Attack","x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T14:00:14.750Z"},"title":"CVE Program Container","references":[{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139438","tags":["x_transferred"]}]}]}}