{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-28003","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","state":"PUBLISHED","assignerShortName":"schneider","dateReserved":"2023-03-09T15:40:32.544Z","datePublished":"2023-04-18T20:43:50.362Z","dateUpdated":"2025-02-05T21:23:55.818Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"EcoStruxure Power Monitoring Expert","vendor":"Schneider Electric","versions":[{"lessThanOrEqual":"PME 2022","status":"affected","version":"All ","versionType":"custom"}]}],"datePublic":"2023-03-14T07:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\n\n\nA CWE-613: Insufficient Session Expiration vulnerability exists that could allow an attacker to\nmaintain unauthorized access over a hijacked session in PME after the legitimate user has\nsigned out of their account.\n\n\n\n"}],"value":"\n\n\nA CWE-613: Insufficient Session Expiration vulnerability exists that could allow an attacker to\nmaintain unauthorized access over a hijacked session in PME after the legitimate user has\nsigned out of their account.\n\n\n\n"}],"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":6.7,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-613","description":"CWE-613 Insufficient Session Expiration","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider","dateUpdated":"2023-04-18T20:43:50.362Z"},"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-01.pdf"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T12:23:30.805Z"},"title":"CVE Program Container","references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-01.pdf","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-02-05T21:23:43.454658Z","id":"CVE-2023-28003","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-02-05T21:23:55.818Z"}}]}}