{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-27975","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","state":"PUBLISHED","assignerShortName":"schneider","dateReserved":"2023-03-09T05:25:56.973Z","datePublished":"2024-02-14T16:55:41.495Z","dateUpdated":"2024-08-02T12:23:30.803Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"EcoStruxure Control Expert","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Versions prior to v16.0"}]},{"defaultStatus":"unaffected","product":"EcoStruxure Process Expert","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Versions prior to v2023"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\nCWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized\naccess to the project file in EcoStruxure Control Expert when a local user tampers with the\nmemory of the engineering workstation.\n\n"}],"value":"\nCWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized\naccess to the project file in EcoStruxure Control Expert when a local user tampers with the\nmemory of the engineering workstation.\n\n"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"NONE","baseScore":7.1,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-522","description":"CWE-522 Insufficiently Protected Credentials","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider","dateUpdated":"2024-02-14T16:55:41.495Z"},"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-044-01.pdf"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2023-27975","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"version":"2.0.3","timestamp":"2024-02-21T20:31:05.372971Z"}}}],"providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-06-04T17:24:48.765Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T12:23:30.803Z"},"title":"CVE Program Container","references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-044-01.pdf","tags":["x_transferred"]}]}]}}