{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-25550","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","state":"PUBLISHED","assignerShortName":"schneider","dateReserved":"2023-02-07T17:00:03.778Z","datePublished":"2023-04-18T20:36:30.681Z","dateUpdated":"2025-02-12T16:00:58.860Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"StruxureWare Data Center Expert","vendor":"Schneider Electric","versions":[{"lessThanOrEqual":"V7.9.2","status":"affected","version":"All","versionType":"custom"}]}],"datePublic":"2023-02-14T08:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>\n\n\n\n\n\n\n\n\n\nA CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that\nallows remote code execution via the “hostname” parameter when maliciously crafted hostname\nsyntax is entered.\n\n \n\n\n\n\n \n\n \n\n Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)</p>"}],"value":"\n\n\n\n\n\n\n\n\nA CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that\nallows remote code execution via the “hostname” parameter when maliciously crafted hostname\nsyntax is entered.\n\n \n\n\n\n\n \n\n \n\n Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)\n\n"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.2,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-94","description":"CWE-94 Improper Control of Generation of Code ('Code Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider","dateUpdated":"2023-04-18T20:36:30.681Z"},"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-045-02.pdf"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.0.9"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T11:25:18.948Z"},"title":"CVE Program Container","references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-045-02.pdf","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-02-05T19:34:20.655945Z","id":"CVE-2023-25550","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-02-12T16:00:58.860Z"}}]}}