{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-22806","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","state":"PUBLISHED","assignerShortName":"icscert","dateReserved":"2023-01-06T18:49:55.855Z","datePublished":"2023-02-15T17:28:53.471Z","dateUpdated":"2025-01-16T21:56:27.143Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"XBC-DN32U","vendor":"LS Electric","versions":[{"status":"affected","version":"Operating System Version 01.80"}]}],"credits":[{"lang":"en","type":"finder","user":"00000000-0000-4000-9000-000000000000","value":"HeeA Go of Dankook University reported these vulnerabilities"}],"datePublic":"2023-02-09T21:04:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>LS ELECTRIC XBC-DN32U with operating system version 01.80 transmits sensitive information in cleartext when communicating over its XGT protocol. This could allow an attacker to gain sensitive information such as user credentials.</p>"}],"value":"LS ELECTRIC XBC-DN32U with operating system version 01.80 transmits sensitive information in cleartext when communicating over its XGT protocol. This could allow an attacker to gain sensitive information such as user credentials.\n\n"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-319","description":"CWE-319 Cleartext Transmission of Sensitive Information","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert","dateUpdated":"2023-02-15T17:28:53.471Z"},"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-23-040-02"}],"source":{"discovery":"EXTERNAL"},"title":"CVE-2023-22806","workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\n<p>LS ELECTRIC is developing mitigations (to be released tentatively by the end of 2023) and recommends users follow the provided workarounds to reduce the risk of exploitation: </p><ul><li>Restrict communication to the PLC to only trusted IP addresses and trusted devices by enabling the “Host Table” option in the configuration window of the PLC. </li></ul>\n\n<br>"}],"value":"\nLS ELECTRIC is developing mitigations (to be released tentatively by the end of 2023) and recommends users follow the provided workarounds to reduce the risk of exploitation: \n\n  *  Restrict communication to the PLC to only trusted IP addresses and trusted devices by enabling the “Host Table” option in the configuration window of the PLC. \n\n\n\n\n\n"}],"x_generator":{"engine":"VINCE 2.0.6","env":"prod","origin":"https://cveawg.mitre.org/api/cve/CVE-2023-22806"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T10:20:31.054Z"},"title":"CVE Program Container","references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-23-040-02","tags":["x_transferred"]}]},{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-01-16T20:56:40.532393Z","id":"CVE-2023-22806","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-01-16T21:56:27.143Z"}}]}}