{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2023-2003","assignerOrgId":"0cbda920-cd7f-484a-8e76-bf7f4b7f4516","state":"PUBLISHED","assignerShortName":"INCIBE","dateReserved":"2023-04-12T14:08:51.192Z","datePublished":"2023-07-13T11:25:03.096Z","dateUpdated":"2024-10-30T16:04:09.807Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"Vision1210","vendor":"Unitronics","versions":[{"status":"affected","version":"4.3, build 5"}]}],"credits":[{"lang":"en","type":"finder","user":"00000000-0000-4000-9000-000000000000","value":"Carlos Antonini Cepeda"}],"datePublic":"2023-07-06T10:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<span style=\"background-color: rgb(255, 255, 255);\">Embedded malicious code vulnerability in Vision1210, in the build 5 of operating system version 4.3, which could allow a remote attacker to store base64-encoded malicious code in the device's data tables via the PCOM protocol, which can then be retrieved by a client and executed on the device.</span>\n\n"}],"value":"Embedded malicious code vulnerability in Vision1210, in the build 5 of operating system version 4.3, which could allow a remote attacker to store base64-encoded malicious code in the device's data tables via the PCOM protocol, which can then be retrieved by a client and executed on the device.\n\n"}],"impacts":[{"capecId":"CAPEC-636","descriptions":[{"lang":"en","value":"CAPEC-636: Hiding Malicious Data or Code within Files"}]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.1,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-506","description":"CWE-506: Embedded Malicious Code","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"0cbda920-cd7f-484a-8e76-bf7f4b7f4516","shortName":"INCIBE","dateUpdated":"2023-07-17T10:11:18.273Z"},"references":[{"url":"https://www.incibe.es/en/incibe-cert/notices/aviso-sci/embedded-malicious-code-vulnerability-unitronics-vision1210"},{"tags":["related","technical-description"],"url":"https://www.hackplayers.com/2023/07/vulnerabilidad-vision1210-unitronics.html"}],"source":{"advisory":"INCIBE-2023-0253","discovery":"EXTERNAL"},"title":"Embedded malicious code vulnerability in Unitronics Vision1210","x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T06:05:27.093Z"},"title":"CVE Program Container","references":[{"url":"https://www.incibe.es/en/incibe-cert/notices/aviso-sci/embedded-malicious-code-vulnerability-unitronics-vision1210","tags":["x_transferred"]},{"tags":["related","technical-description","x_transferred"],"url":"https://www.hackplayers.com/2023/07/vulnerabilidad-vision1210-unitronics.html"}]},{"affected":[{"vendor":"unitronics","product":"vision1210","cpes":["cpe:2.3:h:unitronics:vision1210:-:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","versions":[{"version":"4.3, build 5","status":"affected"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-10-30T16:03:15.608159Z","id":"CVE-2023-2003","options":[{"Exploitation":"poc"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-10-30T16:04:09.807Z"}}]}}